Idiomas disponibles

NUMBER
NAME
21
SHIELD
22 - 23
MOTOR
24
+24 VDC
25
0 VDC
6 - REMOTE CONTROL LEARNING
The learning of a transmitter can be enabled with the "UP" button of the control unit or with the hidden key of a transmitter already
memorized.
The BIOS1 24V POWER control unit can memorize up to 4 functions in as many keys of the remote control. During the learning
procedure, described at paragraph 6.1, a single key is stored. So, it will be necessary to carry out up to 4 learnings for the
assignment of all possible functions.
The functions will be assigned following the order below:
1st memorized key: STEP-BY-STEP function.
2nd memorized key: PARTIAL OPENING function.
3rd memorized key: OPEN function.
4th memorized key: CLOSE function.
6.1 - LEARNING OF A TRANSMITTER
Make sure that the board is out from any programming menus.
1.
To quit, press briefly the "MENU" button until the display shows the state
of the control unit.
2.
Press and release the "UP" button. The display shows rad.
3.
Press the key of the remote control to be memorised within 10 seconds.
If the memorisation has been successful, the display shows don or fnd
4.
(transmitter already memorized).
After 2 seconds the display will show the memory location of the
5.
memorized transmitter (for example 235).
To memorise another key of the remote control (or a new transmitter), repeat the procedure from the point 2.
WARNING! - after 10 seconds of inactivity, the control unit exits from the learning phase (the display shows tout).
8 / 28
Connect the antenna shield.
24Vdc MOTOR power supply.
+24Vdc "POWER BOARD" power supply.
0Vdc "POWER BOARD" power supply.