adjustment of this parameter it is recommended to perform a complete movimentation (opening and closing) before trying the
obstacle detection.
Lower values correspond to a greater thrust on the obstacle.
The intervention for obstacle stops the automation and makes a short inversion of the movement.
5. RUNNING SPEED SPn
Adjust the running speed to ensure a correct functioning of the automation. It is possible to adjust the percentage of speed between
50% and 100%.
WARNING - after the amendment of this parameter, it is necessary to carry out a new setting of the strokes.
6. SLOWDOWNS SPEED SPL
Adjust the slowdowns speed to ensure a correct functioning of the automation. It is possible to adjust the percentage of speed
between 10% and 100% of the running speed SPn.
WARNING - after the amendment of this parameter, it is necessary to carry out a new setting of the strokes.
7. STEP-BY-STEP CONFIGURATION (SS) SBS
It is possible to set 5 different working modes for the SS command:
SBS = 0 : normal (AP-ST-CH-ST-AP-ST-CH-...).
Typical functioning of Step by Step. During the movement a SS command stops the automation.
SBS = 1 : alternated STOP (AP-ST-CH-AP-ST-CH-...).
Alternated functioning with STOP during the opening. During the opening phase a SS command stops the automation.
SBS = 2 : alternated (AP-CH-AP-CH-...).
The user cannot stop the automation during the movement with a SS command. A SS command during the movement
inverts the movement.
SBS = 3 : condominium – timer.
A SS command only opens the automation. When the automation is completely open, if the command persists the control
unit will wait until the opening of the contact before beginning the contdown of the automatic reclosing (if enabled),
another SS command in this phase will restart the contdown of the automatic reclosing.
SBS = 4 : condominium with immediate auto reclosing.
Like condominium – timer (previous point) but during the countdown a SS command will close the automation.
8. BEHAVIOR AFTER THE BLACKOUT blt
When the control unit switches on after a black-out, the behaviour of the control unit depends on the parameter blt:
blt = 0 : no action – when the control unit turns on the automation doesn't move until the first command. The first
movement is an opening.
blt = 1 : closing – at the turning on of the control unit it will perform a closing.
9. AMPLITUDE OF SLOWDOWN AREAS LSI
With this parameter it is possible to adjust the amplitude of the slowdown and eventually disable it ( LSI= 0 ). If you need more
precise or different slowdown between opening and closing it is possible to set the parameter LSI on P (personalized) and perform
an advanced learning of strokes providing also the beginning of slowdowns during the learning.
10. ANTI SLIPPING / EXTRA TIME ASL
This parameter is used if the motor slips, the control unit adds asL seconds to the movement, to ensure a complete movement
of the automationalso in the worst conditions.
11. USAGE OF THE ENCODER ENC
Parameter to determine how the motor encoder is used.
Enc = 0 : Not used.
Enc = 1 : Detect obstacle and position.
Enc = 2 : Detect obstacle.
Enc = 3 : Detect position.
16 / 28
ENG
firmware BIOS124P01
6-1622399 rev. 1