POWER BOARD
C
• M4: 24V motor output
• M5: 24V input for power supply
• CB: Battery charger connector (optional)
3 - PRELIMINARY CHECKS
WARNINGS!
Gate features must be uniformed with the standards and laws in force. The door/gate can be automated only if it is in
a good condition and if its conditions comply with the EN 12604 norm.
The installation must be carried out only by qualified personnel.
Before starting the installation check that:
• The gate shall move frictionless.
• The door/gate leaf should not have a pedestrian opening. In the opposite case it is necessary to take the appropriate steps,
in accordance with EN12453 norm (for instance: by preventing the operation of the motor when the pedestrian opening is
opened, by installing a safety microswitch connected with the control panel).
• Don't generate entrapment points (for example between the open door of the gate and the gate)
• Besides the electrical or mechanical limit switches available on the operators, there must be, on both ends of the installation,
a fixed mechanical stopper which stops the gate in the unlikely event of bad functioning of the limit swithces on the operators.
For this reason the fixed mechanical stopper must be of an adeguate size to withstand the static and kinetic forces generated
by the gate (A) (Fig. 3).
• The guide must be provided with two mechanical stops at its ends (A) (Fig. 4) to avoid the unintentional gate release.
WARNING! Eliminate the mechanical stops of the kind described by Fig. 4.
No mechanical stop shall be on top of the gate, since mechanical stops are not safe enough.
A
6-1622399 rev. 1
firmware BIOS124P01
M4
• F4: Fuse 30A for 24Vdc accessories protection
• C: Cable connector for communication between power
board and control board
Fig. 3
A
ENG
+ -
M5
CB
F4
Fig. 2
Fig. 4