5 - ELECTRICAL CONNECTIONS
WARNING! Before making the connections, be sure that the control unit is not powered up.
SECURITY DIP-SWITCH: Set to "ON" to disable inputs EDGE, PH2, PH1 and STOP.
Eliminates the need to bridge the terminal board inputs
WARNING - with the dip switch ON, the safety devices are disabled.
CONTROL BOARD
ANTENNA
20
21
SHIELD
DIP SWITCHES
TO ENABLE AND DISABLE
SAFETIES
1
SAFETY
EDGE DRY
OR RESISTIVE 8k2
CONTACT N.C. - R.CO.O
(OPTIONAL)
POWER BOARD
6 / 28
2
3
4
5
6
7
8
9
STOP
DRY
CONTACT
N.C.
230V 50Hz
10
11 12 13 14 15 16 17 18 19
FLASHING LAMP
24Vac 25W
COURTESY
LIGHT OUTPUT
24Vac 25W
N
PE
L
FUSE
24V
M
22
ENG
firmware BIOS124P01
TRANSFORMER
230V / 23V 50Hz
RX
TX
CLOSING PHOTO
24Vdc 5W MAX
RX
TX
OPENING PHOTO
24Vdc 5W MAX
TRANSFORMER
230V / 23V 50Hz
+ -
23
24
25