PARAMETERS
Safety edge test:
ted
13
0 = disabled.
1 = enabled.
LPo
14
Partial opening.
TPC
15
Auto reclosing time from partial opening (0 = disabled).
Blinker output mode:
FPR
16
0 = fix.
1 = blinking.
TPR
17
Pre-flashing time (0 = disabled).
Courtesy light settings:
0 = at the end of the movement, light ON for a TCY time.
1 = on if the automation is not closed + TCY time.
FCY
18
2 = on if the courtesy light timer (TCY) is not expired.
3 = open automation light on/off.
4 = open automation light with proportional flashing.
tCy
19
Courtesy light time.
DEAD-MAN mode:
dea
20
0 = disabled.
1 = enabled.
Threshold of cycles for assistance request. Once the limit is
reached the next cycles will be done with fast blinking (only if
ser
21
FPr is enabled).
0 = disabled.
Continuous blinking for assistance request (done only with closed
automation):
sef
22
0 = disabled.
1 = enabled.
r1m
23
Not in use.
mpr
24
Pressure of the motor in closed position.
mre
25
Function for the mechanical relaxation of the motor.
SFT
26
SOFT STOP function.
enp
27
Time of motor encoder
Restore default settings depending on the motor type:
0 = KALOS XL POWER
def
28
1 = KALOS XL POWERSPEED
2 = not in use
trs
29
Viewing of the memory location for a single transmitter.
trC
30
Cancellation of a single transmitter.
18 / 28
DESCRIPTION
2
2
ENG
DEFAULT
KALOS
MIN
XL 24
POWER
0
0
30
0
0
0
1
0
0
0
0
0
180
0
0
0
0
0
0
0
0
0
0
0
10
0
22
4
0
0
firmware BIOS124P01
MAX
UM
1
100
%
900
s
1
10
s
4
900
s
1
x 1000
100
cicli
1
480
min
x 50
10
ms
x 100
20
ms
80
ms
2
6-1622399 rev. 1