– Opened: light on.
– Closed: light off.
– Stopped: 2flash + long wait + 2flash + long wait + ...
19. COURTESY LIGHT TIME tCY
Activation time of the courtesy light.
20. DEAD-MAN MODE DEA
During the DEAD MAN functioning mode the automation moves only with a permanent command.
The enabled commands are OPEN and CLOSE. SS and PED are disabled. During the dead man functioning all the automatic
movements are disabled, like short or total inversions. All safety devices are disabled except for STOP.
21. SETTING THE CYCLES THRESHOLD FOR ASSISTANCE REQUEST SER
It is possible to set a number of cycles before the request of assistance. Once the limit is reached, the next cycles will be done
with a fast blinking (only if fpr = 1 ).
22. CONTINUOUS FLASHING LIGHT FOR ASSISTANCE REQUEST SEF
Once the limit sef is reached the flashing light will blink also with the automation closed to show the request of assistance.
23. PARAMETER R1M
Not in use.
24. PRESSURE OF THE MOTOR IN CLOSED POSITION MPr
This function is used to keep the pressure of the motors on the mechanical stop, performed only with closed automation. The
control unit performs 1 minute of closing every mpr minutes to keep the pressure on the mechanical stops..
WARNING - Do not use with sliding gates.
25. MECHANICAL RELAXATION MrE
Function for the mechanical relaxation of the motor: it is useful on those motors that have the unlock for the manual movement
which can remain locked due to the pressure of the motor on the mechanical stop. When it arrives on the mechanical stop, opening
or closing, the motor will do a short inversion of MrE x 50ms.
NOTE - with MPr with function enabled (pressure of the motor in closed position), the mechanical relaxation is performed only on
the first positioning on the mechanical stop.
WARNING - Do not use with sliding gates.
26. SOFT STOP FUNCTION SFT
Through the sft parameter it is possible to adjust the decelleration ramp in case of voluntary user stop or in case of photocell in-
tervention. WARNING! The parameter does not change the decelleration ramp in case of coast intervention. Range from 0 seconds
(0) to 2 seconds (20) of decelleration.
27. TIME OF MOTOR ENCODER ENP
Encoder output pulse length, at motor full speed.
28. RESTORE DEFAULT SETTINGS DEF
With the item of the menu def it is possible to restore the default settings of the control unit. The reset will restore all the parameters
of the base and advanced menu, but doesn't modify the learnt strokes.
Move to def then press and hold the "MENU" button until the display shows a number (for example 0), then release the button.
Select the used motor with the "UP" and "DOWN" buttons:
•
0 : KALOS XL POWER.
•
1 : KALOS XL POWERSPEED.
•
2 : not used.
Press and hold the "MENU" button until the number stops blinking, then release the button. Press and hold the "MENU" button, the
display will show a count down d80, d79, ..., d01 don't release the button until the display showns DoN.
WARNING - to know the type of the selected motor, move on the item menu def: the display shows alternating the def and the
selected motor. If a parameter changes (that depends on the motor type, see chapter 8.7), on the display will also appear the letter
c (for example c 1).
6-1622399 rev. 1
firmware BIOS124P01
ENG