NUMBER
NAME
1-2
EDGE
3-10
PH2 - COM
4-10
PH1 - COM
5-10
STOP - COM
6-10
OPEN - COM
7-10
CLOSE - COM
8-10
PAR - COM
9-10
SS - COM
10
COM
11-12
FLASH
13-14
OGL
15
+24VDC
16
GND
17
+24VDC TX PHOTO
18-19
ELECTRICAL LOCK
20
ANTENNA
6-1622399 rev. 1
Safety edge input (NC contact). Select the type of the used safety edge (mechanical
or resistive) through the advanced menu EDM and the mode of intervention with the
advanced menu ied.
WARNING - with DIP EDGE on "ON" the input is disabled.
Opening photocell input (NC contact). The photocell intervenes at any time during
the opening of the automation system and stops immediately the movement; the
automation system will continue the opening when the photocell beam is free. In the
event of intervention on closure (parameter Ph2 = 0), the automation stops and, when
the beam is free, moves on opening.
In the advanced item Ph2, it is possible to select the behaviour of the photocell.
WARNING - with DIP PH2 on "ON" the input is disabled.
Closing photocell input (NC contact). The photocell intervenes at any time during the
closing of the automation system, stops immediately and inverts the movement. The
photocell doesn't intervene during the opening.
In the advanced item sph it is possible to select the behaviour of the photocell with the
closed automation.
WARNING - with DIP PH1 on "ON" the input is disabled.
Connect the STOP command (NC contact). This input is classified as a safety device; the
opening of the contact stops immediately the automation and it remains blocked up to
the restoring of the state of the input contact.
WARNING - with DIP STOP on "ON" the input is disabled.
Connect the button for the OPEN command (NO contact).
Connect the button for the CLOSE command (NO contact).
Connect the button for the PARTIAL OPENING command (NO contact).
Connect the button for the STEP-BY-STEP command (NO contact).
Common for safety and command inputs.
Flashing light output at 24Vac. Use a flashing light without self flashing card 24Vac
25W max.
Courtesy light / Open automation light output at 24Vac. Use a light 24Vac 25W max.
The functioning of the auxiliary light and its activation time are managed from advanced
menu FCY and tcy.
+24Vdc accessories power supply. Used for the receiver of the photocells.
0Vdc accessories power supply.
WARNING - The control unit supplies up to a maximum of 200 mA (5W) for the
accessories at 24Vdc.
+24Vdc accessories power supply. Used for the transmitter of the photocells. This
connection is necessary in case of use of the photocells test. It is possible to enable the
photocells test from the advanced menu tph.
Connect Electrical Lock contact.
WARNING! Use external power, the terminals only give activation contact.
Connect the antenna.
firmware BIOS124P01
DESCRIPTION
ENG
7 / 28