PARAMETERS
SPN
5
Running speed.
SPL
6
Slowdowns speed.
Step-by-Step configuration:
0 = normal (AP-ST-CH-ST-AP-ST...).
1 = alternated STOP (AP-ST-CH-AP-ST-CH...).
sbs
7
2 = alternated (AP-CH-AP-CH...).
3 = condominium - timer.
4 = condominium with immediate auto reclosing.
Behavior after the blackout:
blt
8
0 = no action.
1 = closing.
Amplitude of the slowdown areas.
LSI
9
0...100% = percentage of the stroke.
P = personalized during the learning.
asL
10
Anti slipping / Extra time.
Use of the Encoder:
0 = Not used.
ENC
11
1 = Detect obstacle and position.
2 = Detect obstacle.
3 = Detect position.
NOTE - the parameters highlighted in grey depend on the selected motor. In the table are reported the data of the KALOS XL POWER
motor. For more information, refer to chapter 8.7.
1. AUTO RECLOSING TIME TCL
Active when the automation is in the completely open position, the automation automatically closes after tCL. seconds. In this
phase the display shows -TC with the blinking dash, that during the last 10 seconds will be replaced by the count down. An
opening command or the photocells intervention restarts the counting.
2. AUTO RECLOSING TIME AFTER TRANSIT ttr
If in the opening phase or in the completely open position the beam of the photocells is obscured and freed, the automation
automatically closes after ttr seconds when the completely open position is reached. In this phase the display shows -tC with
the blinking dash, that during the last 10 seconds will be replaced by the count down.
3. OBSTACLE SENSITIVITY WITH RUNNING SPEED SEn
Adjust the obstacle sensitivity to ensure a correct functioning of the automation, it must stop if there is an obstacle but also it
must ensure the complete movement in the worst conditions (exp. winter, hardening of motors, etc). After the adjustment of this
parameter it is recommended to perform a complete movimentation (opening and closing) before trying the obstacle detection.
Lower values correspond to a greater thrust on the obstacle.
The intervention for obstacle stops the automation and makes a short inversion of the movement.
4. OBSTACLE SENSITIVITY DURING SLOWDOWNS AREA SEL
Adjust the obstacle sensitivity during the slowdown to ensure a correct functioning of the automation, it must stop if there is an
obstacle but also it must ensure the complete movement in the worst conditions (exp. winter, hardening of motors, etc). After the
6-1622399 rev. 1
DESCRIPTION
firmware BIOS124P01
ENG
DEFAULT
KALOS
MIN
MAX
XL 24
POWER
100
50
100
50
10
100
0
0
4
0
0
1
20
0
100
15
0
300
0
0
3
UM
%
%
%
s
15 / 28