8 - PROGRAMMING OF THE CONTROL UNIT
8.1 - DISPLAY
By pressing the "DOWN" button it is possible to read on the display the following parameters.
DISPLAY
State showing (--, OP, CL, ...)
Maneuvers performed, e.g.:
02.0. (units) / 001 (thousands), that is 1020 cycles.
8.2 - STATE OF THE CONTROL UNIT
DISPLAY
DESCRIPTION
--
Standby - Automation closed or after the switch on of the control unit.
OP
Opening phase.
CL
Closing phase.
SO
Automation stopped by the user during the opening.
SC
Automation stopped by the user during the closing.
HA
Automation stopped by an external event (photocells, stop).
oP
Automation opened without automatic reclosing.
PE
Automation opened on partial opening position without automatic reclosing.
-tc
Automation opened with auto reclosing; in the last 10 seconds the dash will be replaced by the countdown.
Automation opened on partial opening position with auto reclosing; in the last 10 seconds the dash will be
-tP
replaced by the countdown.
12 / 28
DESCRIPTION
Description of the control unit state. Refer to the follow table for the
description of the single states of functioning.
Maneuvers count: the display shows alternately the thousands (without
dots) and the units (with dots).
ENG
firmware BIOS124P01
6-1622399 rev. 1