Time
Activity
Daily
Visible inspection of the high pres-
sure hoses
check brush
Check warning boards at the wash-
ing place
Check the unit for leaks
Check filling level of the detergent. Check filling level, refill if necessary.
Check fill level of fuel tank
Everyday un-
Check frost protection devices
der frost con-
ditions
Cleaning the sieve
Clean the filter of the anti freeze pump. Clean the filter and replace
After 40 oper-
Check oil level of the high pressure
ating hours or
pump
once a week
Check oil level
Check the salt reserve in the salt
container (optional)
Check the level of the water soften-
er (optional)
Hardness of the water check ( by
bse exchanger option)
Clean the brush shaft
After 80 oper-
Clean and maintain housing
ating hours or
once every
two weeks
After 160 op-
Clean the filter of the cleaning
erating hours
agent by using the cleaning agent
or once a
cotainer.
month
Check the salt container ( by base
exchanger optional)
Lubricate the door hinges
Oil the locks, doors , the control cir-
cuit doors, and the coin container.
After 250 op-
Check pump head
erating hours
or once every
Check the pump hose in the dosing
six months
pumps
Adjust ignition electrodes, replace
if required.
before the
Check frost protection devices
frosting period
Before the
check the anti freeze water amount
frosting period
at the anti freeze cycle
and on month-
ly basis during
the frosting pe-
riod.
After 500 op-
Check the high pressure pump
erating hours
thoroughly
or once a
Oil change in high pressure pump See Maintenance tasks
year
Desoot the heating coil, adjust
burner
Decalcify the heating coil
Clean the fuel container
Maintenance schedule
Performance
Check high pressure hoses for mechanical damages such as scraping, visible hose
duck, bends, porous and cracked rubber. Replace damaged high pressure hoses.
concerning dirt, damage and waerout. If the bristles are shorter than 30mm, change
them. In the winter time, if it is –5 °C check several times a day besause of ice lock the
foam washing. Exchange the combi. steel pipe with the high pressure-steel pipe.
Check whether the warning boards for the users are available and legible.
Check pumps and pipes for leaks. Inform Customer Service if there is oil under the high
pressure pump, if more than 3 drops of water drop out of the high pressure pump when
the pump is running.
Check filling level, refill if necessary.
Is the hot air ventilator working? Is the anti freeze cycle functioning (anti freeze water
amount approximately 0,5 l/min)? Is the drain of the brush shaft to the swimming con-
tainer free of ice?
Open the screw ( one top of the high-pressure pump), take out the strainer and clean
it, put the strainer back in, close the screws tight.
The oil level must lie between the MIN and MAX markings; else refill.
Milky oil indicates that it contains water. Inform Customer Service.
Is the salt level above the water level? If required, top up softening salts.
Check filling level; refill the softener RM 110, if required.
Take water from the fresh water container, and check the hardness by using the inspec-
tion set B ( ording number: 6.768-003) . Target value: below 3 °dH
Remove the dirt from the brush shaft.
Clean the housing thoroughly from inside and outside. After cleaning conserve it with
high grade steel agent (ordering number: 6.290-911).
Remove filter and rinse it thoroughly with hot water.
Check water level (approx. 5 ... 25 cm above the sieve plate).
Check for deposits; if required, empty the tank, clean it, fill it up with softening salts and
start it up again. Risk of functional disturbances. While filling the softening salts, use
only the softening salt in the tablet form listed in the chapter "Accessories".
Lubricate the hinges with grease (order no.: 6.288-072).
Spray care liquid (order no. 6.288-116) into the locks.
Check the pump hose for cracks and wear; replace if required.
Change the freezing thermostat in the direction of "check", until the anti freeze equip-
ment is turned on. Fan heater and freezing cycle must start. If the temperature is above
5 °C in addition, turn the thermostat of the fan heater up. Then turn the frost protection
thermostat in an anti-clockwise direction until the stop. Reset the thermostat of the hot
air blower.
Note
The openings in the equipment socket may not be closed, otherwise the function of the
anti freeze thermostat is interrupted.
Target value: approx. 0.5 l/min
Water quantity is higher: Change the node piece in the hand-spray gun.
Water quantity is lesser Clean filter for frost protection pump; clean sieve in throttle,
clean pipes, check the rotation direction of the pump.
See Maintenance tasks
See Maintenance tasks
12
-
EN
By whom
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Customer
Service
Operator/
Customer
Service
Customer
Service
Operator
Operator
Customer
Service
Operator
Customer
Service
Trained op-
erator
Operator
35