Interruption
Possible cause
base exchanger
No power supply
does not regenerate
Switch clock at the head of the base exchanger
is wrong adjusted or, after an interruption of the
power supply was not adjusted.
The water stays
No salt in the salt tank
hard after the regen-
erartion
No sole suction
water input pressure is too low
Other interruptions can only be removed by
the Service.
Accessories
Attachment sets
Additional feature swinging arm comfort
order number: 2.639-743
Additional feature swinging arm
order number: 2.640-942
Additional feature thermostat
order number: 2.639-753
Additional feature half load valve
order number: 3.640-262
Additional feature anti theft device
order number: 2.641-120
Sticker operation instruction
German, order number: 5.391-180
English, order number: 5.391-181
French, order number: 5.391-182
Italian, order number: 5.391-183
Spanish, order number: 5.391-184
Portuguese, order number: 5.391-185
Dutch, order number: 5.391-186
Greek, order number: 5.391-187
Swedish order number: 5.391-189
Finnish, order number: 5.391-190
Norwegian, order number: 5.391-191
Danish, order number: 5.391-192
Estnish, order number: 5.391-193
Lithuanien, order number: 5.391-194
Lettish, order number: 5.391-195
Russian, order number: 5.391-196
Polish, order number: 5.391-197
Hungarian, order number: 5.391-198
Czech, order number: 5.391-199
Slowakian, order number: 5.391-200
Romanian, order number: 5.391-202
Croatian order number: 5.391-203
Water filter G 1"
order number: 6.414-278
container
Cleaning agent container 25 liter
order number: 6.393-474
Without content.
Fuel container 40 liter
order number: 6.393-209
Without content.
Cleaning agent container 10 liter
order number: 6.393-480
Without content.
Lid for the cleaning agent container 10 liter,
order number: 6.393-045
38
Interruptions at the base exchanger (optional)
Repair
Check power supply (fuse, switch, jack).
Set the time at the switch clock.
Fill in salt, let the level of the salt not get below the water level. Operator
Increase the water pressure to the minimum of 0,2 MPa (2 bar)
.
Fuel
Motor oil Hypoid SAE 90
order number: 6.288-020
Silicon grease
Order no. : 6.288-072.0
Lock grease
Order no. : 6.288-116.0
Steel care product
Order no. : 6.290-911.0
Water softening salt in form of tabletts
order number: 6.287-016
25 kg, for option base exchanger
Softener RM 110
For the optional softener:
Detergent
Warning!
Before using the cleaning agent, please re-
fer to the notice on the package. Do not use
the following cleaning agents:
cleaning agent containing nitrit acid
–
cleaning agent containing active chlo-
–
rinate
If you use such cleaning agents, it will dam-
age your equipment.
CHEM 1
RM 806 ASF
CHEM 2
RM 820
CHEM 3
RM 821
The cleaning agents are to be used undiluted.
Lime solvent
RM 100 ASF
RM 101 ASF
Warranty
The warranty terms published by our com-
petent sales company are applicable in
each country. We will repair potential fail-
ures of your accessory within the warranty
period free of charge, provided that such
failure is caused by faulty material or de-
fects in fabrication. In the event of a warran-
ty claim please contact your dealer or the
nearest authorized Customer Service cent-
er. Please submit the proof of purchase.
EN
Only use accessories and spare parts
–
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts
ensures that the appliance can be oper-
ated safely and trouble free.
For additional information about spare
–
parts, please go to the Service section
at www.kaercher.com.
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
Notice
The equipment may only be installed by an
mechanic of Kärcher
–
or an from Kärcher authorized individual
–
Preparing the installation place
The following requirements are necessary
in order to install the equipment:
The plant may be used for diverting com-
bustible gases only in the open.
If the plant is to be housed under a roof or in
a closed room, then it must be connected to
a chimney to provide an outlet for the exhaust
gases. If the plant is to be connected to a
chimney, then the burner needs to be adjust-
ed and the exhaust values must be checked
by the concerned chimney cleaner.
Straigh even area, with a solid subsoil
–
with the measures of 1040x725 mm.
For the option of the base exchanger/Os-
–
mose an additional area of 845 x 725 mm.
Using the option of the base exchanger/
–
Osmose: Water connection with pipe
separator according to DIN 1717, per-
forming data, refer to " technical data".
Please pay attention to the national re-
quirements (in Germany DVGW).
Power connection, refer to "technical
–
data".
By customer, lockable, access for the
–
wash customer emergency - off- main
switch.
15
-
By whom
Operator, Main-
tenance
Operator
Operator
Spare parts
Transport
Storage
Installing the unit
(only for experts)