Adjustment control circuit
board
Menue point
adjustment Option
Warm-Water
Progr. 1
warm/ cold
Progr. 2
Progr. 3
Progr. 4
Time-Base
Time-Base:
30...300 s
Wash-Time
Progr. 0
100...50%
Progr. 1
Progr. 2
Progr. 3
Progr. 4
Progr. 5
Coin-Amount
Channel 1:
10...200
Channel 2:
Channel 3:
Channel 4:
Channel 5:
Channel 6:
Options
Halfload
On/Off
Osmosis
Version
Version: x.x
Statistics
Coin
Today: Coins
Counter
Total: Coins
Timer
Total: hours
HP-Pump
S001: hours
S002: hours
Timer Burner Total: hours
S010: hours
S020: hours
Timer-Pro-
Progr 1: hours
grams
Progr.2: hours
Progr.3: hours
Progr.4: hours
Progr.5: hours
Error
Error: Exxx
Message
Service
Service:
Sxxx
*) Reset coin sum- daily counter: Push the "<" and ">" for two
seconds at the same time.
Remove this page, cut above this field, und put it inside the door of the control board. A copy of this brief
instruction does stay in the operation instruction (refer to next page)
Brief instruction SB-WASH
Interruptions and service
announcements control
circuit board
Standard
setting
Error
Cause
warm
codes
cold
E001
Motor protection switch -Q1 or development temper-
warm
ature switch of the HD-Pumpe has triggered off
cold
Winding protection contact motor
90 s
E002
Fuse - F1 has triggered, circulating pump, heat fan
100%
E003
Interruption warm water heater
60%
E004
Osmosewater is empty (Option)
90%
E005
Cleaning agent container/fluel empty /Option)
70%
E100
Interruption control circuit
60%
60%
Servicecode Meaning
10
S001
pump head HD-pump
20
S002
HD-Pump totally
40
S010
Burner lid ( starter)
10
S020
fuel valve, burners are blacking
20
40
Menue navigation
Off
Off
*)
Button
OK, for 2 seconds
<, >
OK
ESC
EN
Intervall
250 h
500 h
250 h
500 h
Action
open the menue
change values, turn menue
Confirm
cancel, exit
18
-
Brief Instructions
for maintenance and
servicing
Please pay attention to the section "maintenance and serv-
ice" in the operation instructions!
DAILY
Checl high pressure hose
check brush
Check information notices in the equipment
Check the pipe line and high pressure pump for tightness
Check the content of the cleaning agent container
Check the content of the fuel container
DAILY IF FROST
Check and if needed clean the fan heater and the anti freeze cycle
After 40 operating hours, or weekly
Check oil level of the high pressure pump
Check the oil condition of the high pressure pump (is there water
in the oil?)
Clean the brush shaft and the floaing container
EVERY 14 DAYS
Clean and service the housing of the total equipment
After 160 operating hours, or monthly
Clean the coin mechanism.
Clean the filter of the cleaning agent container
Grease the joints at the doors
AFTER 250 OPERATING HOURS OR SEMI-ANNUALLY
Check pump head (Customer Service)
Adjust ignition electrode, replace if required (customer service)
BEFORE THE FROST PERIOD
Check the anti freeze equipment of its function
BEFORE THE FROST PERIOD AND DURING THE FROST
PERIOD MONTHLY
Check the freezing water amount
After 500 operating hours, or yearly
Change the oil and high pressure pump
Clean the soot of the heating coils and decalcify (Maintenance)
Adjust burner (Customer Service)
Clean the fuel container
base exchanger (optional)
Pay attention to the saltusage, check daily
Refill the salt, if the water level is above the salt
Check salt container, remove sludge
The suction jet of the salt container must be put to the grounf of
the container
The gree light at the E-equipmentboard is blinking => base ex-
changer does regenerate
PROPORTION EQUIPENT HAS TO BE DECALCIFIED RM
110 (OPTION)
Pay attenetion to the amount used of the RM110, check daily
Red light at the E-equipment board => container empty
41