10 Attachment
Maximum Applicable Motor
Drive Model
2008
2010
2012
2018
2021
5.5 (7.5)
2030
7.5 (10)
2042
2056
2070
18.5 (25)
2082
Three-Phase 400 V Class
Table 10.10 Factory-Recommended Branch Circuit Protection: Three-Phase 400 V
Maximum Applicable Motor
Drive Model
4001
0.37 (1/2)
4002
0.75 (1)
4004
4005
4007
368
Output
kW (HP)
ND
HD
1.5 (2)
1.1 (1.5)
2.2 (3)
1.5 (2)
3.0 (4)
2.2 (3)
4.0 (5)
3.0 (4)
4.0 (5)
5.5 (7.5)
11 (15)
7.5 (10)
15 (20)
11 (15)
15 (20)
22 (30)
18.5 (25)
Output
kW (HP)
ND
HD
0.37 (1/2)
0.55 (3/4)
1.5 (2)
1.1 (2)
2.2 (3)
1.5 (3)
3.0 (4)
2.2 (3)
YASKAWA TOMPC7106173UA GA500 Installation and Operation Instruction
Time Delay
Fuse
Class J, CC,
and T Fuse
Rated Current
A
12
15
20
30
35
50
70
90
110
125
Class
Time Delay
Fuse
Class J, CC,
and T Fuse
Rated Current
A
3
3.5
7
9
12
Semiconductor Protection
Fuse Rated Current
Manufacturer: EATON/
Bussmann
Fuse Rated
Current
Model
A
FWH-70B
70
FWH-70B
70
FWH-70B
70
FWH-90B
90
FWH-90B
90
FWH-100B
100
FWH-150B
150
FWH-200B
200
FWH-200B
200
FWH-225A
225
Semiconductor Protection
Fuse Rated Current
Manufacturer: EATON/
Bussmann
Fuse Rated
Current
Model
A
FWH-40B
40
FWH-40B
40
FWH-50B
50
FWH-70B
70
FWH-70B
70