left display, whereas the message H.XX
will appear on the right display, where
XX indicates the selection of the adhe-
sive weight application enabled on the
machine;
• The
key can be used to change
this configuration to H3, H6 or H12;
• Press
to confirm the selection
made and exit the function;
- for the application of the balancing weights,
refer to the following table:
Type of weight
Traditional
spring
Adhesive
Adhesive
Adhesive
The positions on the wheel of H 3, H 6 and
H 12 are shown in Figure 11b.
User manual S 63
Weight application
position
Always H 12
H 3
H6
H12
11b
BALANCING
PROGRAMMES
Before starting a balancing operation, the
following steps must be followed:
- fit the wheel on the hub using the most
suitable flange;
- lock the wheel so that no movement
is possible during the wheel spin and
braking phases;
- remove any counterweight, pebble, dirt
or other foreign body;
- set the wheel's geometric data correctly.
Dynamic balancing (standard)
Proceed as follows to balance a wheel in
dynamic mode:
- Press the
LED corresponding to the STD pro-
gramme illuminates.
- Press the key
selection.
This programme is automatically launched
when the machine is switched on.
- Set the wheel's geometric data.
- Spin the wheel by lowering the guard.
To obtain the most accurate results, do
not apply any undue stress to the machine
during wheel spin.
- Wait for the wheel to stop automatically
and for the calculated unbalance values
to be displayed.
- Select the first side to be balanced.
- Turn the wheel until the central element
of the corresponding position indicator
lights up.
- Apply the indicated balancing weight in
the position on the rim corresponding to
12 o'clock.
keys until the
to confirm the