ELECTRICAL
HOOK-UP
On request, the wheel balancer can be set
up by the manufacturer to operate with
the power supply available in the place
of installation. The set-up data for each
machine are given on the machine data
plate and on a special label attached to the
power supply connection cable.
WARNING
Any operations for hooking up to the
workshop electrical board must be carried
out only by qualified technicians in compli-
ance with the regulations in force, under
the responsibility and at the charge of
the customer.
- The electrical hook-up must be performed
according to:
• absorbed power specifications indi-
cated on the machine data plate.
• the distance between the machine and
the electric hook-up point, so that voltage
drops under full load do not exceed
4% (10% when starting up) of the rated
voltage specified on the data plate.
- The user must:
• connect the machine to its own electrical
connection fitted with a suitable 30-mA
current sensitive circuit breaker;
• fit power supply protection fuses sized
in compliance with specifications in the
main wiring diagram of this manual;
• provide the workshop electric installa-
tion with an efficient grounding circuit.
- Prevent unauthorised use of the machine,
always disconnect the power supply plug
when the machine is not used (switched
off) for extended periods of time.
- If the machine is connected directly to
the power supply by means of the main
electrical board and without the use of a
plug, install a key-operated switch or suit-
able lock-out device to restrict machine
use exclusively to qualified personnel.
48
WARNING
For the correct functioning of the machine
it is vital to have a good ground connec-
tion. NEVER connect the machine ground
wire to a gas pipe, water pipe, telephone
cable or any other unsuitable object.
COMPRESSED AIR
HOOK-UP
WARNING
The compressed air hook-up may only
be performed if the pneumatic ring nut
is supplied (optional accessory supplied
on request).
WARNING
All compressed air hook-ups must be
carried out by qualified personnel only.
- The hook-up to the workshop compressed
air system must ensure a minimum pres-
sure of 8 bar.
- A universal union is used for connection to
the compressed air system. No special or
additional adaptor is needed for connec-
tion. A pressure-resistant hose with 6mm
inner diameter and 14mm outer diameter
must be fastened to the notched union using
the clamp provided with the machine.

SAFETY REGULATIONS

WARNING
Non-compliance with the instructions and
danger warnings can cause serious injuries
to the operator or other persons.
Do not operate the machine until you
have read and understood all the danger/
warning notices in this manual.
In order to operate the machine correctly, it
is necessary to be a qualified and authorised
operator, able to be trained and to know the
User manual S 63