- Press the key
selection.
- After the selection, the machine will
display the message:
• CAL on the left-hand display;
• GO on the right-hand display.
- Perform a first spin.
- At the end of the spin, fix the calibration
weight supplied with the machine on the
swinging unit bell as indicated in figure18.
- Perform a second spin.
- At the end of the spin, change the position
of the calibration weight on the swinging
unit bell as indicated in figure 19.
User manual S 63
illuminates.
to confirm the
18
- Perform a third spin.
This last calibration phase includes the
execution of three consecutive spins in
automatic mode.
At the end of the spin(the message "End
CAL" will appear on the display), if the
calibration has been successful, an acoustic
consent signal goes off at the end of the
spin otherwise the message E 2 is temporar-
ily displayed.
NOTES
- Once the procedure is finished, remove
the calibration weight.
- Pressing the key
interrupt the programme at any time.
- THE CALIBRATION PERFORMED IS
VALID FOR ANY TYPE OF WHEEL!
Sensor calibration
width (if present)
This procedure is used to calibrate the po-
tentiometer of the external sensor (width).
It must be performed when the machine
requests it by displaying the E4 message,
or when the measured and the actual rim
widths differ.
- Press the
luminous dot corresponding to the CAL
19
it is possible to
keys until the
69