The floor must be strong enough to support
a load equal to the weight of the equipment
plus the maximum load allowed. The support
base on the floor and the envisaged fixing
means must also be taken into account.
Environmental operating conditions must
comply with the following requirements:
- relative humidity ranging from 30% to 80%
(without condensation);
- temperature ranging from 0° to +50°C.
WARNING
For information concerning the techni-
cal features, warnings and maintenance
instructions consult the related operator
manuals provided with the documentation
of the machine.
WARNING
The machine must not be operated in
potentially explosive atmospheres.
The machine is supplied partially disas-
sembled and is to be assembled according
to the procedures described below.
Head assembly (fig.3/3a)
- Remove the head rear closing plate
(C, Fig.3);
- Loosen the 4 screws M8 (A, Fig.3) that fasten
the head to the body on the rear side
without unscrewing them completely;
- Remove the head from the 4 fastening
44
screws pulling them first towards the left
and then towards the rear side of the
machine;
- Turn the head to a vertical position and
insert the 4 fastening holes on the M8
screws on the body (B, Fig.3a), making
sure that the previous loosened screws
do NOT touch the head itself;
- Tighten the fastening screws on which the
head is positioned;
- Fit the previously removed head closing
plate.
Installing the wheel guard with
the corresponding mounting
- Fit the protective support on the pin
located on the head;
1
- Turn the support until the holes on the
support itself are aligned with those on
the pin; then fix the two parts using the
included screw (Fig. 4a);