USER'S MANUAL. OD-405/410B/411/415
Parameters
Y1:
Y2:
Y1Y2
V/A (OD-411/415)
Cursors adjustment
1.
To move the upper cursor, pres Y1, and then use the VARIABLE [3]
knob.
2.
To move the low cursor press Y2, and the use the VARIABLE [3]
knob.
3.
To move both cursors, press Y1 Y2, and then use the VARIABLE [3]
knob.
4.
Press Cursor to remove the onscreen cursors.
5.3

Math operations

The Math operations can add, subtract, multiply or perform FFT/FFT
RMS on the input waveforms. The resulted waveform can be measured using
the cursors, and saved or recalled just like normal input signals.
Addition (+)
Subtraction (—)
Multiplication (x)
FFT
Page 45
Voltage level of the upper cursor.
Voltage level of the lower cursor.
The difference between the upper and lower
cursor.
The voltage / current difference (Y1-Y2).
Adds amplitude of CH1 & CH2 signals.
Extracts the amplitude difference between CH1
& CH2.
Multiplies CH1 and CH2 (OD-411, OD-415
only).
Performs FFT calculation on a signal. Four
types of FFT windows are available: Hanning,
Flattop, Rectangular, and Blackman.