USER'S MANUAL. OD-405/410B/411/415
5.11.1 Saving the panel settings
Procedure
1.
(For saving to USB flash drive) Insert the USB flash drive into the
front panel USB port.
2.
Press Save/Recall key twice to recall the Save menu.
3.
Press Save Setup.
4.
Press Destination repeatedly to select the saved location. Use the
Variable Knob to change the internal memory location (S1~S15).
Memory: Internal memory S1~S15.
USB: USB, no practical limitation for the amount of files. When
saved, the setup file will be placed in the root directory.
5.
Press Save to confirm saving. When completed, a message appears
at the bottom of the display.
NOTE:
The file will not be saved if the power is turned off or the USB
flash drive is removed before completion.
5.11.2 Saving the waveform
Procedure
1.
(For saving to USB flash drive) Insert the USB flash drive into the
front panel USB port.
2.
Press the Save/Recall key twice to access the Save menu.
3.
Press Save Waveform.
4.
Press Source. Use the Variable Knob to select the source signal.
CH1 ~ CH2: Channel 1 ~ 2 signal.
Math: Math operation result.
Ref A, B : Internally stored reference waveforms A, B.
Page 85
11-2011