8
Ex relevant specifications acc. to cFMus
8.1
Overview of the different output options
Versions
Version I
Output option A1, A2, H1, H2
in the order number
Version II
Output option A3, H3
in the order number
8.2
Electrical data for Div. 2 / Zone 2
8.2.1
Version I: Active / passive current outputs and Version II: passive / passive current outputs
Model FCx3xx-F2, FCT3xx-F2
Current output 1
Terminals 31 / 32
Current output 2
Terminals 33 / 34
Pulse output
Terminals 51 / 52
Switching output
Terminals 41 / 42
Switching input
Terminals 81 / 82
All inputs and outputs are electrically isolated from one other and from the power supply.
Class I Div. 2
— Current output 1: Active
— Current output 2: Passive
— Pulse output: Active / passive, switchable
— Switching input and output: Passive
CoriolisMaster FCB330, FCB350, FCH330, FCH350 | CI/FCB300/FCH300-X1 Rev. F EN - 39
Class I Div. 1
— Current output 1: Active
— Current output 2: Passive
— Pulse output: Passive
— Switching input and output: Passive
— Current output 1: Passive
— Current output 2: Passive
— Pulse output: Passive
— Switching input and output: Passive
Type of protection NI
Vmax
(V)
o
30
30
30
30
30
Imax
(mA)
o
30
30
65
65
10