Construction Compacte - ABB Sensyflow FMT500-IG Instrucciónes De Puesta En Marcha

Ocultar thumbs Ver también para Sensyflow FMT500-IG:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 159
1.6.3
Transmetteur de construction séparée
1
2
3
6
7
8
9
Fig. 3
1.6.4

Construction compacte

1
2
3
4
5
6
7
8
9
Fig. 4
1 Fabricant de l'appareil, pays d'origine, année de
fabrication
2 Désignation de l'appareil, numéro de fabrication
3 Code de commande, numéro d'ordre SAP
4 Alimentation électrique autorisée, fréquence
5 Puissance absorbée maximale, version matérielle
6 Numéro de type interne
7 Température ambiante admissible, classe de
protection
CI/FMT500-IG-X1
Automation Products GmbH
Alzenau
Germany 2007
Sensyflow FMT500-IG
O-Code : V14224-6A111111100
Typ - Nr.: xxxx
Tamb = -25...+80 °C
IS CLASS I DIV1 Group: A,B,C,D , CLASS I Zone 0 AEx ia IIC T4...T1
DIP CLASS II,III DIV1 and 2 Group: E,F,G
NI CLASS I,II,III DIV2, Group: A,B,C,D, CLASS I Zone 2 Group: IIC T4...T1
Intrinsically safe Exia CLASS I DIV1 Group: A,B,C,D Ex ia IIC T4...T1
CLASS II,III DIV1 and 2 Group: E,F,G
CLASS I DIV2, Group: A,B,C,D Ex nA II T4...T1
when connected per drawing V14224-6...12 2,V14224-6...22 2
T4/T3 Tmed. = -20...100 °C; T2 Tmed. = -20...200 °C; T1 Tmed. = -20...300 °C;
Tmax. med. = 150 °C
x = 1 HART Version SAP Option Communication 1
x = 2 PROFIBUS Version SAP Option Communication 2
Automation Products GmbH
Alzenau
Germany 2007
Sensyflow FMT500-IG
O-Code : V14224-6A111111100
Voltage: 110...230 V DC/AC +/-10 %, 48...62 Hz
Power: max. 20 VA
Typ - Nr.: xxxx
Tamb = -25...+50 °C
XP CLASS I DIV1 Group: B,C,D CLASS I , Zone 1 II B T4...T1
IS Circuits for CLASS I DIV1 Group: B,C,D , CLASS I Zone 0 AEx ia IIC
DIP CLASS II,III DIV1 and 2 Group: E,F,G
NI CLASS I,II,III DIV2, Group: A,B,C,D,F,G CLASS I Zone 2 Group: IIC T4..T1
CLASS I DIV1 Group: B,C,D,F,G CLASS I , Zone 1 II B T4...T1
CLASS I Zone 1 / 0 Ex d [ia] [ib] IIC T4...T1 or Ex d [ia] IIC T4...T1
CLASS II,III DIV1 and 2 Group: E,F,G
CLASS I,II,III DIV2, Group: A,B,C,D,F,G CLASS I Zone 2 Ex nA II T4...T1
when connected per drawing V14224-7...11x2, V14224-7...21x2
T4/T3 Tmed. = -20...100 °C; T2 Tmed. = -20...200 °C; T1 Tmed. = -20...300 °C;
Tmax. med. = 150 °C
x = 1 HART Version SAP Option Communication 1
x = 2 PROFIBUS Version SAP Option Communication 2
Sensyflow FMT500-IG
S/N: XXX5NNNN
8323455772
HW-Rev: 1.01
IP 66, NEMA 4X
x
S/N: XXX5NNNN
8323455772
HW-Rev: 1.01
IP 67, NEMA 4X
Résistance d'entrée
FMT500
0102
x
FMT500
0102
8 Identification pour la protection
antidéflagrante, p. ex.
homologation FM
9 Identification pour la protection
antidéflagrante, p. ex.
homologation CSA
10 Type d'appareil
11 Observer la documentation
produit
12 Marquage CE (Conformité CE)
10
11
12
G00849
10
11
12
G00850
FR - 9

Publicidad

Tabla de contenido
loading