Mätvärdessensor Åtskild Konstruktion; Kompakt Utförande - ABB Sensyflow FMT500-IG Instrucciónes De Puesta En Marcha

Ocultar thumbs Ver también para Sensyflow FMT500-IG:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 159
1.6.3
Mätvärdessensor åtskild konstruktion
1
2
3
6
7
8
9
Fig 3
1.6.4
Kompakt utförande
1
2
3
4
5
6
7
8
9
Fig 4
1 Apparattillverkare, ursprungsland, tillverkningsår
2 Apparatbeteckning, tillverkningsnummer
3 Beställningskod, SAP-uppdragsnummer
4 Tillåten energiförsörjning, frekvens
5 Maximal prestanda, hårdvaruversion
6 internt typnummer
7 Tillåten omgivningstemperatur, kapslingsklass
CI/FMT500-IG-X1
Automation Products GmbH
Alzenau
Germany 2007
Sensyflow FMT500-IG
O-Code : V14224-6A111111100
Typ - Nr.: xxxx
Tamb = -25...+80 °C
IS CLASS I DIV1 Group: A,B,C,D , CLASS I Zone 0 AEx ia IIC T4...T1
DIP CLASS II,III DIV1 and 2 Group: E,F,G
NI CLASS I,II,III DIV2, Group: A,B,C,D, CLASS I Zone 2 Group: IIC T4...T1
Intrinsically safe Exia CLASS I DIV1 Group: A,B,C,D Ex ia IIC T4...T1
CLASS II,III DIV1 and 2 Group: E,F,G
CLASS I DIV2, Group: A,B,C,D Ex nA II T4...T1
when connected per drawing V14224-6...12 2,V14224-6...22 2
T4/T3 Tmed. = -20...100 °C; T2 Tmed. = -20...200 °C; T1 Tmed. = -20...300 °C;
Tmax. med. = 150 °C
x = 1 HART Version SAP Option Communication 1
x = 2 PROFIBUS Version SAP Option Communication 2
Automation Products GmbH
Alzenau
Germany 2007
Sensyflow FMT500-IG
O-Code : V14224-6A111111100
Voltage: 110...230 V DC/AC +/-10 %, 48...62 Hz
Power: max. 20 VA
Typ - Nr.: xxxx
Tamb = -25...+50 °C
XP CLASS I DIV1 Group: B,C,D CLASS I , Zone 1 II B T4...T1
IS Circuits for CLASS I DIV1 Group: B,C,D , CLASS I Zone 0 AEx ia IIC
DIP CLASS II,III DIV1 and 2 Group: E,F,G
NI CLASS I,II,III DIV2, Group: A,B,C,D,F,G CLASS I Zone 2 Group: IIC T4..T1
CLASS I DIV1 Group: B,C,D,F,G CLASS I , Zone 1 II B T4...T1
CLASS I Zone 1 / 0 Ex d [ia] [ib] IIC T4...T1 or Ex d [ia] IIC T4...T1
CLASS II,III DIV1 and 2 Group: E,F,G
CLASS I,II,III DIV2, Group: A,B,C,D,F,G CLASS I Zone 2 Ex nA II T4...T1
when connected per drawing V14224-7...11x2, V14224-7...21x2
T4/T3 Tmed. = -20...100 °C; T2 Tmed. = -20...200 °C; T1 Tmed. = -20...300 °C;
Tmax. med. = 150 °C
x = 1 HART Version SAP Option Communication 1
x = 2 PROFIBUS Version SAP Option Communication 2
Sensyflow FMT500-IG
S/N: XXX5NNNN
8323455772
HW-Rev: 1.01
IP 66, NEMA 4X
x
S/N: XXX5NNNN
8323455772
HW-Rev: 1.01
IP 67, NEMA 4X
FMT500
0102
x
FMT500
0102
8 Märkning för explosionsskydd,
t.ex. FM-godkännande
9 Märkning för explosionsskydd,
t.ex. CSA-godkännande
10 Apparattyp
11 Beakta produktdokumentationen
12 CE-tecken (EU-konformitet)
Säkerhet
10
11
12
G00849
10
11
12
G00850
SV - 9

Publicidad

Tabla de contenido
loading

Tabla de contenido