Error Codes; Error Description - Cebora PLASMA PROF 180 HQC Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.5

Error codes

Errors are divided into two categories:
Hardware errors [E]: these cannot be reset and therefore require the power source to be restarted. They are
displayed on the screen with a red background.
Alarms [W]: these are associated with an external condition that can be reset by the user and do not therefore require
the power source to be restarted. These are displayed on the screen with an amber background.
Code
TYPE

Error Description

2
[E]
Error in the power source control board
EEPROM memory
6
[E]
The power source does not communicate
with the gas console or with the cooling unit
7
[E]
The power source does not communicate
with the interface circuit
9
[W]
The gas console does not communicate with
the power source
16
[E]
Continuous voltage lower than minimum
accepted value
26
[E]
Problem with the internal clock
27
[E]
Error in the power source control board
FLASH memory
30
[E]
Current detected in module IGBT1 with arc off Contact the CEBORA Service Department
31
[E]
Current detected in module IGBT2 with arc off Contact the CEBORA Service Department
35
[E]
Current measurement off the scale in module
IGBT1, during cutting
36
[E]
Current measurement off the scale in module
IGBT2, during cutting
39
[E]
Current detected in pilot arc circuit, with arc
off
40
[E]
Hazardous voltage: fault in power circuit
49
[E]
Current detected in pilot arc circuit, during
cutting
55
[E]
Electrode exhausted
58
[E]
Error during firmware updating
68
[E]
Mains voltage does not meet specifications
ACTION
Contact the CEBORA Service Department
Check the connection between the power source
and the gas console or the cooling unit.
If the problem persists, contact the CEBORA
Service Department.
Contact the CEBORA Service Department
Check connection between power source and
gas console.
If the problem persists, contact the CEBORA
Service Department.
Contact the CEBORA Service Department
Contact the CEBORA Service Department
Contact the CEBORA Service Department
Contact the CEBORA Service Department
Contact the CEBORA Service Department
Contact the CEBORA Service Department
Contact the CEBORA Service Department
Contact the CEBORA Service Department
Replace electrode and/or nozzle.
Check the consumables are correctly fitted,
depending on the type of work.
Also check that the correct cutting gas is being
used.
Contact the CEBORA Service Department
Check the fuses in the electrical cabinet where
the power source mains cable is connected.
If the problem persists, contact the CEBORA
Service Department.
121/128

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Plasma prof 300 hqc968969

Tabla de contenido