Starting The Configuration - SICK T4000 Multi Instrucciones De Operación

Ocultar thumbs Ver también para T4000 Multi:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6
Chapter
Tab. 4:
Setting the DIP
switches
Note
160
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice 8011036/TF94/2010-06-29
Configuration
DIP-
Switch setting OFF
switch
(left)
1
No sensor on terminals
H1a, H1b, SH1
2
No sensor on terminals
H2a, H2b, SH2
3
No sensor on terminals
H3a, H3b, SH3
4
No sensor on terminals
H4a, H4b, SH4
5
Automatic reset
(no RESET button
connected)
6
External device
monitoring not
connected
Close all monitored protective devices.
6.2

Starting the configuration

Start the teach-in process:
Do not interrupt supply voltage or open protective
devices during the teach-in process.
Switch on operating voltage,
for "manual Reset" operating mode depress
RESET button until end of the Teach-in process
(or apply 24 V to terminal S for Teach-in process),
wait for self-test; the green LED STATE flashes
during the self-test at 15 Hz for about 10 s.
The teach-in process will now start automatically;
the green LED STATE flashes at 1 Hz during the
teach-in process.
The teach-in process takes about 10 s; the LEDs will
indicate whether the teach-in process was success-
ful:
Operating instructions
T4000 Multi
Switch setting ON
(right)
Sensor on terminals
H1a, H1b, SH1
Sensor on terminals
H2a, H2b, SH2
Sensor on terminals
H3a, H3b, SH3
Sensor on terminals
H4a, H4b, SH4
Manual reset
(RESET button
connected)
External device monitor-
ing connected