Concluding The Configuration; Error During Configuration - SICK T4000 Multi Instrucciones De Operación

Ocultar thumbs Ver también para T4000 Multi:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operating instructions
T4000 Multi
8011036/TF94/2010-06-29 © SICK AG • Industrial Safety Systems • Germany • Subject to change without notice
Configuration
the green LED STATE goes out and the yellow LED
OUT and the red LED DIA are also off: the teach-in
process was successful,
the green LED STATE flashes three times with a
repetition after 1 s and the red LED DIA comes
on: the teach-in process was not successful and
must be repeated.
6.3

Concluding the configuration

After successful teach-in process
switch off operating voltage for at least 10 s,
remove bridge between terminals J1 and J2.
6.4

Error during configuration

If teach-in process was not successful, repeat
teach-in process; avoid the following sources of
error:
status change during teach process (e.g. opening
a protective device),
no DIP switch in ON position,
DIP switch setting and connected configuration
do not correspond,
terminals J1 and J2 were bridged while the supply
voltage was switched on,
supply voltage was interrupted during teach-in
process.
6
Chapter
161

Publicidad

Tabla de contenido
loading

Tabla de contenido