Datos Generales - Perkins E70M Manual Del Usuario

Tabla de contenido

Publicidad

476-5308
Marine Gen Set Power
Perkins E70 TAGM Auxiliary
Basic Technical Data
Number of Cylinders
Cylinder Arrangement
Cycle
Induction System
Combustion System
Bore
Stroke
Compression Ratio
Cubic Capacity
Direction of Rotation
Firing Order
Total Weight (wet)
Total Weight (dry)
Overall Dimensions
Item
Engine Speed
Net Engine Power
Brake Mean Effective Pressure
Piston Speed
Engine Coolant Flow (FW) Max
Raw Water Flow Max
Combustion Air Flow
Exhaust Gas Flow
Exhaust Gas Temperature
Total Heat From Fuel
Gross Heat to Power
Net Heat to Power
Heat to Water and Lubricating Oil
Heat to Exhaust
Heat to Radiation
Heat to Aftercooler
N41675
6
Vertical in-line
4 stroke
Turbo after cooled
Direct injection
105 mm
135 mm
16.5:1
7.01 litres
Anti-clockwise view from flywheel
1, 5, 3, 6, 2, 4,
1212 kg
1157 kg
Height = 1260 mm
Length = 1928 mm
Width = 956 mm
General Installation Data - Typical Installation Conditions
Units
rev/min
kW
bar
m/s
litre/min
litre/min
3
m
/min
3
m
/min
O
C
kW
kW
kW
kW
kW
kW
kW
Typical Average Sound Pressure Level at 1 Metre
1500 rev/min = 86.5
1800 rev/min = 88.9
Note
All data based on operation under ISO/TR14396, ISO 3046/1 standard
reference conditions
Test Conditions
O
Air temperature 25
C (77
relative humidity 30%, all ratings certified within ± 5%
If the engine is to operate in ambient conditions other than the test
conditions then suitable adjustments must be made for any change in
inlet air temperature, barometric pressure or humidity.
Diesel Fuel
ISO-F-DMX/ISO-F-DMA/ISO 8217:1986 (E) Class F, EN590, D975, JIS
class 1,2,3
Lubricating Oil
A multrigrade lubricating oil must be used which conforms to specification
API-CJ4
Start/Load Delay
90% of prime power can be applied 10 seconds after the starter motor is
energized. The remaining 10% can be applied 30 seconds after start if the
ambient temperature is not less than 15
O
less than 15
C, an immersion heater is recommended.
Type of Operation and Application
Prime Power
Tag1
Tag2
Tag3
109.3
129.0
163.9
12.47
14.71
18.7
6.8
6.8
240
240
240
138.5
138.5
138.5
9.48
10.47
11.78
19.86
22.25
25.32
418.0
433.0
443.4
304.4
353.5
426.2
109.3
129.0
163.9
109.3
129.0
163.9
89.4
101.5
117.8
82.1
94.9
110.0
8.2
8.1
15.4
19.9
26.2

8. Datos generales

Performance
dBA ( Complete with a Typical Alternator)
dBA ( Complete with a Typical Alternator)
O
F) barometric pressure 100 kPa (29.5 in Hg),
O
C. If the ambient temperature is
110%
Tag1
Tag2
1500
120.2
141.9
13.71
16.19
6.8
6.8
6.8
240
240
138.5
138.5
9.77
10.55
20.6
22.55
428.0
438.0
326.7
372.5
120.2
141.9
120.2
141.9
94.3
104.9
87.2
97.1
8.3
8.2
8.2
16.8
20.5
Capítulo 8
Tag3
180.3
20.57
6.8
240
138.5
11.81
25.51
446.3
448.4
180.3
180.3
121.4
111.7
8.3
26.7
7684-1-14
Página 41

Publicidad

Tabla de contenido
loading

Tabla de contenido