12.5 Power supply

The stations are supplied with electrical power from a power supply unit with an output voltage of
24 V DC (max. 4 A).
The entire station is supplied with electrical power from the rack PLC.

12.6 Loading PLC programs

Proceed as described in the user's manuals for the programming software used in order to load the PLC
program.
Current PLC programs can be found on the Internet at the following website:
www.ip.festo-didactic.com

12.7 Starting the sequence

1. Check the power supply and compressed air supply.
2. Before resetting, manually remove the workpieces from the module and station transfer points.
3. Turn the key switch to the horizontal position.
4. Place at least one workpiece in the stacking magazine.
5. Perform a reset procedure. The reset procedure is prompted by the RESET button lighting up and is
executed once the button has been pressed.
6. Turn the key switch to the vertical position.
7. The LED on the start button lights up (the system is ready to start).
8. Press the start button.
9. The station starts the sequence.
The sequence can be interrupted at any time by pressing the EMERGENCY STOP
button or at the end of the cycle by pressing the STOP button.
The following applies when several stations are combined:
The individual stations are aligned in the reverse order to the flow of materials.