Display
Press
Display
Factory Setting
Display
Press
Step 5
P5: Two options for signalling a fault
condition with alarm relays F1 and F2.
Press button so that P5 appears in display.
o1 (Option 1) P4 is set to default of
normally open.
F1 relay contact
a) Low-level fault will cause F1
contact to repeatedly open and close.
b) Pressure fault will cause F1
contact to close and stay closed.
F2 relay contact
Low-level fault or pressure fault will cause
F2 contact to close and stay closed.
o2 (Option 2) P4 is set to default of
Normally Open.
F1 fault relay's contact will close on
low-level fault and stay closed.
F2 fault relay's contact will close on
pressure fault and stay closed.
Both contacts can be used for remote
signalling.
Press pushbutton to change to option 1.
Display
P6: Upon applying power to pump, program
whether it starts with pause time SP or
starts with lube cycle SO.
in display.
cycle is to start with pause time or
lubricating time.
with pause time SP (start pause time).
start with lubricating time SO (start
operation). After first lubricating time preset
pause time will be valid.
26
Press
Display
Press
Press button, so that P6 appears
Currently set values appear as to whether
Default setting for pump is set to start
Press button.
Each time pump is switched on, it will
Step 6