Specifications
Electrical data for
pump
Incoming voltage
Maximum current
External fuse
Reverse polarity protection
Current draw with ignition switch open
Electrical data for AC pump
Incoming voltage
Maximum current
Frequency
Output from power supply
External Fuse
Common electrical data for
and AC pumps
Minimum pause time
Maximum pause time
Pause time increments
Maximum pumping time
Enclosure rating
Rating for fault relay contact:
Switching voltage
Switching current
Minimum switching current
Pump P653S
Operating pressure with:
-pressure switch
-pressure transducer
End of line pressure switch setting
End of line pressure transducer setting
End of the line transducer vent pressure is factory preset at
900 psi (62 bar). Pressure can be adjusted from
200 to 1 000 psi (14 to 70 bar) in 100 psi (7 bar) increments.
Maximum distance using shielded wire for
pressure transducer
Operating temperature range for
Operating temperature range for AC pumps 32 to 122 °F
Number of outlets (see instructions)
Lubricant
Output
Reservoir sizes, L
Lubricant line connection size
See list of approved and recommended lubricants. Contact Lincoln if lubricant is not in list.
1)
Lubricant output is measured at + 70 °F (21 °C) and backpressure 1 450 psi (100 bar). Different pressures, temperature and grease can change output results.
2)
* Indicates change.
24 V
-20%/+30%
10 A
10 A (time delay)
Yes
25 mA
100 to 240 V AC
1.7 A
47 to 63 hz
24 V
at 5 A
3 A (time delay)
4 min.
59 hours 59 min.
1 min. or 1 hour
12 min.
IP 6K9K (NEMA 4X)
Max. 230 V AC/120 V AC/
24 V
Max. 1 A inductive
0.1 mA
3 500 psi (240 bar)
3 500 psi (240 bar)
(transducer can be
adjusted from
1 400 to 4 600 psi
(96 to 317 bar)
2 500 psi (172 bar)
(not adjustable)
2 500 psi (172 bar)
not adjustable
98 ft (30 m)
pumps –40 to 158 °F
1)
(–40 to 70 °C)
1)
1)
(0 to 50 °C)
1)
1
up to NLGI grade 2
1)
1.5 in
/min
3
2)
(24,6 cm
/min)
3
4, 8, 15 and 20
G
/
in
1
4
Pump elements K7
Piston diameter
Number of pumping elements
Tightening torques
Install pump
Electric motor on housing
Pump element in housing
Closure plug in housing
Return line connector on housing
Tie rods for 15 and 20 l reservoir
Weights
15 l reservoir with 3 pump elements K7,
without pressure relief valve, empty
Pump P653S without connecting cable
Pump P653S version 1A
Pump P653S version 3A
8 l reservoir, standard
Pump P653S without connecting cable
Pump P653S version 1A
Pump P653S version 3A
4 l reservoir, standard
Pump P653S without connecting cable
Pump P653S version 1A
Pump P653S version 3A
Weights above include the following equipment:
Pump kit with three pump elements, pressure relief valve,
grease filling (1,5 kg)
Packing (cardboard box)
Attaching parts
Operating Instructions
Installation
Use only high pressure 5 000 psi (344 bar) minimum hydraulic hose for
supply lines. Use only hose connection fittings that are appropriate for
programmed/preset system pressure.
31
7 mm
3 (connected together)
13.3 ft.lbf (18 Nm)
8.8 ft.lbf (12 Nm)
14.57 ft.lbf (20 Nm)
8.8 ft.lbf (12 Nm)
8.8 ft.lbf (12 Nm)
7.4 ft.lbf (10 Nm)
21.1 lb (9,6 kg)
23.3 lb (10,6 kg)
24.6 lb (11,2 kg)
19.8 lb (9,0 kg)
21.1 lb (9,6 kg)
24.6 lb (11,2 kg)
19.8 lb (9,0 kg)
21.3 lb (9,7 kg)
23.1 lb (10,5 kg)