Display
Press
Display
Press
NOTE
P8 programming parameter only appears if
pump has external pressure transducer
connected.
P8: Programs setting of where external
pressure transducer will open. Opening point
(vent pressure) is adjustable from 200 to
1 000 psi (13,8 to 69 bar) in 100 psi (6,9 bar)
increments. Factory set opening point (vent
pressure) is 900 psi (62 bar). Closing point of
external pressure transducer is fixed in
software at 2 500 psi (172 bar).
Press button to change value.
Reading x 100 = Transducer setting in psi
9 x 100 = 900 psi (62 bar).
Step 8
Display
Press
Complete programming
Press button. P - is displayed.
NOTE
Always carry out programming completely in
order to save new values.
• Press additional lubrication to complete
programming and to save entered
parameters.
NOTE
If button additional lubrication is not
pressed within 30 seconds, changed
parameters will not be saved and previous
programming remains valid.
NOTE
After completion of programming, check
parameter settings in review mode.
Programming of pump with pressure
transducer is complete.