1.2 Technical data
Note:
The instruments Multimat2 Touch und Multimat2 Touch+Press are delivered in one of for 2 different voltage systems,
including a power lead (as required for the country in which it is operated):
• 100 – 125 Volt ~ / 50/60 Hz
• 230 – 240 Volt ~ / 50/60 Hz
Check the voltage rating of your instrument on the type plate, which is located on the rear of the instrument. Make sure that
the voltage rating and the supplied power cord are appropriate for your local power network.
Power consumption
Pump connection
Overvoltage category
Protection class
Instrument fuses
Degree of contamination
Weight
Dimensions H/W/D
Dimensions H/W/D
Pressing pressure
1.3 Environment conditions
Environment temperature:
Relative humidity:
Altitude:
44
Multimat2 Touch
1,350 W (without vacuum pump)
As mains voltage, max. 2.5 A
II
I
2x 16 A medium slow,
6.3 mm x 32 mm, 250 V
2
22 kg
441/320/425 mm closed
585/320/425 mm open
2 °C to 40 °C
80 % at 31 °C
max. 3500 m above sea level
Multimat2 Touch+Press
1,350 W (without vacuum pump)
As mains voltage, max. 2.5 A
II
I
2x 16 A medium slow,
6.3 mm x 32 mm, 250 V
2
25 kg
593/320/425 mm closed
748/320/425 mm open
2.7 bar

Publicidad