code displayed
controller
remote
causes
term.*
P
H
2 fast
E102
over-current at the electrodes;
flashes
probable electrode malfunction
red
or water conductivity
LED
temporarily too high (especially
when starting after a short
stop)
3 fast
E103
power not available; with the
flashes
machine on no steam is
red
produced
LED
not
E105
high supply water conductivity
featured
4 slow
E113
excessive reduction in
flashes
production
red
LED
3 slow
E114
no water
flashes
red
LED
not
E115
excessive foam in the cylinder
featured
during boiling
5 slow
E116
drain malfunction
flashes
red
LED
7 slow
E131
high water conductivity
flashes
pre-alarm
not
E121
high humidity in the room
featured
(high temp. for T control)
not
E122
low humidity in the room
featured
(low temp. for T control)
not
E124
high outlet humidity
featured
10.3 Table of alarms and signals
solution
1. check the operation of the drain
electrovalve
2. check the seal of the fill electrovalve
when not energised
3. drain part of the water and re-start
1. with the machine off and disconnected
from the mains, check the internal
electrical connections
1. check limit set for b6;
2. turn the machine off and clean the water
conductivity measuring electrodes;
3. if the problem persists, change the
source of supply water or install a
suitable treatment system
(demineralisation, even partial).
N.B.: the problem will not be resolved
by softening the supply water.
1. cylinder completely depleted or water
with excessive foam. Perform
maintenance on the cylinder
1. check that the fill pipe from the mains
to the humidifier and the internal pipe
are not blocked or bent and that there
is sufficient pressure (0.1-0.8 MPa,
1-8 bar);
2. check the operation of the fill
electrovalve;
3. check that the steam outlet is not
working against excessive back-pressure,
preventing the flow of water into the
cylinder by gravity;
4. check that the steam outlet pipe is not
is choked and that there are no pockets
of condensate.
the formation of foam is generally due to
the presence of surfactants in the water
(lubricants, solvents, detergents, water
treatment agents, softeners) or an
excessive concentration of dissolved salts:
1. drain the water supply lines
2. clean the cylinder
3. check for the presence of softeners
(in this case, use another type of water
or reduce the softening)
check the drain circuits and the correct
operation of the drain electrovalve
check the conductivity of the supply water
if necessary, install a suitable treatment
system N.B.: the problem will not be
resolved by softening the supply water.
check the operation of the probe and the
limit set for parameter P2
check the operation of the probe and the
limit set for parameter P3
check the operation of the outlet
probe
66
action
reset
display (H)
P
H
total
total
not
shut-
shut-
available
down
down
total
total
not
shut-
shut-
available
down
down
-
total
not
shut-
available
down
total
machine
manual
shut-
disabled
down
total
machine
automatic
shut-
disabled when water
down
returns (see
par. 11.4.10)
-
signal
manual
only
total
machine
manual
shut-
disabled
down
-
signal
auto
only
-
signal
manual
only
-
signal
manual
only
-
signal
manual
only
humiSteam - cod. +030221914 rel. 5.2 - 07.11.2005
alarm
reset
relay
relay (H)
active
not
available
active
not
available
active
not
available
active
manual
active
automatic
when
water
returns
active
manual
active
manual
not
-
active
active
auto
active
auto
active
auto
continues