16. SPECIFIC FOR 3210-3211
Troubleshooting for zones 1 and 2
PROBLEM
E1,E2,E7,C1
Temperature sensor failure
allo of the temperature sensor of the
E3,E4
IGBT.
Failure of the connection between the
EU
display and the main board
EL,EH
Abnormal supply voltage
Temperature sensor of the glass
C3
ceramic hob Is high
IGBT temperature sensor
C2
It is high
Troubleshooting for zones 3 and 4
Fault
code
The supply voltage is higher than the
EL
nominal voltage.
The supply voltage is lower than the
EH
nominal voltage.
High temperature of the ceramic plate
C1,C3
sensor.
C2
High temperature of IGBT .(1#)
POSSIBLE CAUSES
Problem
Contact the supplier.
Contact the supplier.
Contact the supplier.
Check if the power supply is
normal. Switch on after the
is normal.
Please restart after the induction hob
cools down.
Self-Recovery
Check if the power supply is normal.
Switch on after the power supply
food is normal.
Wait for the temperature of the ceramic
hob to return to normal.
Touch the "ON/OFF" button to reset the
unit.
Wait for the IGBT temperature to return
to normal.
Touch the "ON/OFF" button to reset the
unit.
Check if the fan is working properly; if it is
not, call the
SAT Pando technical service.
25
WHAT TO
DO
Solution