Descargar Imprimir esta página

Hella Gutmann mega macs PC SE Manual De Instrucciones página 185

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 454
Hella Gutmann
Proceed as follows to perform the global check with trouble code reading:
1. Perform steps 1 to 11 as described in section Vehicle selection.
CAUTION!
Pulling off of the HG-VCI PC when actuating the clutch
Risk of injury or material damages
Proceed as follows before startup:
1. Apply the parking brake.
2. No gear is engaged.
3. Regard the window with information and instructions.
NOTICE
Danger of short circuit and voltage peaks when connecting the HG-VCI PC
Danger of destruction of automotive electronics
Switch off ignition before connecting the HG-VCI PC to the vehicle.
2. Connect the HG-VCI PC to the vehicle's diagnostic connection.
ð Both LEDs of the HG-VCI PC flash.
ð The HG-VCI PC is ready for operation.
3. Select Diagnostics > Function > Trouble codes.
NOTICE
The selection of the following possibilities depends on the selected manufacturer and vehicle type:
- Functions
- Component groups
- Systems
- Data
4. Select >Global check<.
5. Call up the >Information< tab.
6. Follow the instructions on the screen.
7. Call up the ECU overview with
8. Select further sub-categories where necessary.
ð The device indicates all ECUs installed in the vehicle.
mega macs PC SE
.
Working with the mega macs PC SE | 11.
185

Publicidad