13. | Optional HGS Tools
NOTICE
A blue amp clamp (CP 700) is required for the complete system test. Without an amp clamp, the current in-
tensity is not measured during the starter and alternator tests. The resistor test is not applicable at all.
Proceed as follows to perform the system test:
1. Connect the BPC-Tool to the battery (see operating instructions for the BPC-Tool).
2. Insert the electrical plug connection of the clamp meter into the ST3 connector of the BPC-Tool with the arrow point-
ing up.
3. Select >Optional HGS Tools< in the main menu.
4. Select Battery diagnostics with
5. Select >System test<.
6. Open the list under Temperature measurement with
7. Select the required type of temperature measurement.
8. Repeat steps 6 to 7 for another selection.
9. Open the virtual keypad under Cold cranking amps [A] with
10. Enter a value.
11. Confirm your entry with
12. Start the function System test under Diagnostic type with
ð The connection to the BPC-Tool is established.
ð The system test is started.
From here, the system test is controlled using the keys on the BPC-Tool (see operating instructions of the BPC-Tool).
A summary of the system test is displayed on the BPC-Tool and is automatically imported into the device.
13.1.2. Performing a Battery Test
Proceed as follows to perform the battery test:
1. Connect the BPC-Tool to the battery (see operating instructions for the BPC-Tool).
2. Insert the electrical plug connection of the clamp meter into the ST3 connector of the BPC-Tool with the arrow point-
ing up.
3. Select >Optional HGS Tools< in the main menu.
4. Select Battery diagnostics with
5. Select >Battery test<.
6. Open the list under Battery position with
7. Select >In the vehicle< or >Outside the vehicle<.
220
.
.
.
.
.
where necessary.
.
Hella Gutmann
mega macs PC SE