ELEC
Br
ELECTRIC BILGE PUMP
B
+
–
ELECTRIC BILGE PUMP
1. Check:
• Electric bilge pump operation
Does not operate → Replace.
Checking steps:
• Suspend the electric bilge pump in a con-
tainer filled with water.
• Connect the brown lead terminal to the
positive battery terminal.
• Connect the black lead terminal to the
negative battery terminal.
• Check that the water flows from the elec-
tric bilge pump hose.
FUSE
Refer to "STARTING SYSTEM."
BATTERY
Refer to "ELECTRICAL" in Chapter 3.
MAIN AND FUEL PUMP RELAY
Refer to "IGNITION SYSTEM."
7-45