7. Possible Malfunctions
In case of malfunction, disconnect the device from its power source. Before contacting
the service or sales agent, verify - based on the table below - whether it is possible to
eliminate disruption in operation.
Problem
The device is connected to
the power supply but the
green indicator is off and
the device does not heat.
The heating indicator is
on but temperature
does not rise.
The green power supply
indicator is on but despite
setting the temperature
the heating indicator is off.
Heating element ceases
functioning after some
time.
If you cannot remove the malfunctions:
do not open the body,
-
notify the customer service point or contact the sales
-
agent, while providing the following information:
type of malfunction;
article and serial number (rating plate at the
rear of the device).
Cause
Plug not connected
properly
Safety fuse blown
Overheating protection
has been activated
Interrupted contact with
the heating element
Damaged heating element
Set temperature has been
reached
Damaged temperature
controller.
Damaged indicator light
Overheating protection
has been activated
Solution
Pull the plug and insert it
to the socket again in the
proper way
Check the fuse, check the
device after connecting it
to a different socket
Press RESET button on
the control box
Contact the sales agent.
Contact the sales agent.
Check functioning at
different temperature
Contact the sales agent.
Contact the sales agent.
Press RESET button in
the control box. If the
overheating protection
activates again within a
short time, contact the
sales agent.
- 43 -