Chapter 5
Page 24
Adjust the sideways tray guide rails
The holders of both tray guiding rails have to be fixed with two cap nuts on the left and right sides on the
spring case. The sideways tray guide rails are adjusted correctly when after the adjustment the trays are lo-
cated centrally on the stacking platform and sideways have a distance of 0.2'' (5 mm) to the tray guide rails.
To adjust the sideways tray guide rail, proceed as follows:
Loosen all four cap nuts, but do not unscrew them completely.
Bring the two tray guiding rails evenly in the right position and align them vertically.
Screw the four cap nuts of the tray guiding rails tight.
5.2.2
Adjustments OTA/U-BW
INFO
Adjusting the stop edges
Figure 11
The stop edges are adjusted correctly when after the adjustment the trays are located centrally on the stack-
ing platform and sideways have a distance of 5 mm to the stop edges. The trays rest directly against the ver-
tical plastic stop beads and are flush at the front edge of the platform.
The adjustment mechanism for the stop edges is located below the stacking platform.
Figure 12
To adjust the sideways stop edges, proceed as follows:
Carefully tilt the device so that it rests on the push bars.
Tray dispenser
OTA/47–36 | OTA/53–37 | OTA/58-33 | OTA/53–37 S | OTA/U-BW | OTA-E/BA-4xGN | TAG-1/53-37 | TA-2/53-37 | EBS-T/53-37
Required tools
You need the following tools for changing the stop edge of the cover of the
spring case:
Open-end wrench SW 17,
Philipps screwdriver size 1,
Screwdriver size 7 (chisel width 0.24-0.28'' (6-7 mm) and thickness 0.03-0.04
''(0,8–1,0 mm))
hexagon wrench SW 5 and 0.3'' (8 mm),
knife
Adjust stop edges
Stacking platform (bottom view)
Operation
Adjustment of the open tray dispensers
4330041_A0