Fire Barrier Installation (Fire-Rated Wood Door Only) - Schlage LM9200 Serie Instrucciones De Instalación

Publicidad

1b
Check top strike cutout.
IMPORTANT: THE CUTOUT FOR THE TOP STRIKE MUST BE
ON THE STOP SIDE OF THE DOOR.
If the cutout is not on the stop side of the
door, contact the door distributor.
2

Fire barrier installation (fire-rated wood door only)

2a
Install intumescent.
Fire components must be installed to maintain fire rating of the opening.
Note door handing on intumescent. The intumescent is applied to the side of the fire barrier that will be opposite
the door stop.
Intumescent must be properly aligned before adhesive contacts the fire barrier surface.
Peel one side of the adhesive backing from intumescent as shown.
Apply the intumescent adhesive to the fire barrier.
INSIDE
RH
Right Hand
OUTSIDE
RR
INSIDE
Right Hand
Reverse
OUTSIDE
CAUTION!
Adhesive is permanent and not repositionable.
(1)
OR
(2)
Top strike
cutout
1³⁄₁₆"
2³⁄₄"
Backset
1³⁄₁₆"
of Routing
³⁄₄"
⁹⁄₃₂"
Stop side of door
LH
Left Hand
LR
Left Hand
Reverse
(1)
(2)
⁵⁄₈"
1"
1³⁄₁₆"
Top strike cutout
INSIDE
OUTSIDE
INSIDE
OUTSIDE
3