Wilo Flumen OPTI-TR 20-1 Instrucciones De Instalación Y Funcionamiento página 291

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1092
6.4.1
Maintenance tasks
6.4.1.1
Rotating the propeller
Installation and operating instructions Wilo-Flumen OPTI-TR 20-1, 28-1, 30-1, 40-1 Wilo-Flumen EXCEL-TRE 20, 30, 40
Installation and electrical connection
CAUTION
Material damage due to incorrect fixation
Defective fixation may limit the functionality of the mixer or damage it.
• If the mixer is fixed to a concrete structure, use anchor bolts for fixation. Follow the
manufacturer's installation instructions! Temperature specifications and hardening
periods must be strictly observed.
• If the mixer is fixed to a steel structure, ensure that the structure is sufficiently
strong. Use fixation materials with sufficient strength!
Use suitable materials to avoid electrochemical corrosion!
• Tighten all screwed connections. Observe torque specifications.
NOTICE
Use only properly functioning lifting equipment!
Use only properly functioning lifting equipment to lift and lower the mixer. Ensure
that the mixer does not become jammed during lifting and lowering. Do not exceed
the maximum bearing capacity of the lifting equipment! Check that lifting equip-
ment is functioning properly before use!
▪ Prepare the operating space/installation site:
– Clean, free of coarse solids
– Dry
– Frost-free
– Decontaminated
▪ Work must always be carried out by two persons.
▪ Avoid any painful or tiring body postures.
▪ When working at a height of more than 1 m (3 ft) above the ground, use scaffolding
with a safety harness.
▪ Cordon off the working area around the scaffolding.
▪ Toxic or asphyxiating gases may build up when working in closed rooms. Ensure there is
sufficient ventilation and observe protective measures according to work regulations
(examples):
– Measure the gas concentration before entering.
– Carry a gas detector with you.
– etc.
▪ Take immediate countermeasures if there is a build-up of toxic or asphyxiating gases.
▪ Use hoisting gear to lift, lower and transport the mixer.
▪ Attach the hoisting gear to the attachment point using a shackle. Only use lifting gear
which has been technically approved.
▪ Keep away from the hoisting gear's swivel range when hoisting the product.
▪ Only use hoisting gear if it can be safely attached. The storage place and the installation
site must be accessible with the hoisting gear. The set-down location must have a firm
surface.
▪ Observe minimum clearances with respect to walls and any fixtures.
▪ The laid connection cable must allow safe operation. Check whether the cable cross-
section and the cable length are sufficient for the selected installation type.
After a storage period of more than 6 months, carry out the following maintenance
tasks before installation:
▪ Rotate propeller.
▪ Seal housing oil change.
WARNING
The propeller blade has sharp edges!
Sharp edges can form on the propeller blades. There is a risk of limbs being severed.
Wear safety gloves to protect against cuts.
The mixer is not connected to the mains!
Protective equipment must be put on!
en
291

Publicidad

Tabla de contenido
loading

Tabla de contenido