8.4.1
Ground and wall fixation
8.4.2
Using a lowering device
Installation and operating instructions Wilo-Flumen OPTI-TR 20-1, 28-1, 30-1, 40-1 Wilo-Flumen EXCEL-TRE 20, 30, 40
Shut-down/dismantling
WARNING
A lack of protective equipment may result in hand and foot injuries or the
risk of falling!
Danger of (serious) injuries during work. Wear the following protective equipment:
• Safety gloves for protection against cuts
• Safety shoes
• Safety harness
• Safety helmet must be worn if lifting equipment is used!
WARNING
Risk of burns from hot surfaces!
Motor housing can become hot during operation. It may cause burns. Allow the mo-
tor to cool down at ambient temperature after switching it off!
NOTICE
Use only properly functioning lifting equipment!
Use only properly functioning lifting equipment to lift and lower the mixer. Ensure
that the mixer does not become jammed during lifting and lowering. Do not exceed
the maximum bearing capacity of the lifting equipment! Check that lifting equip-
ment is functioning properly before use!
Mixer decommissioned.
Operating space emptied, cleaned and, if required, disinfected.
Mixer cleaned and, if required, disinfected.
Ensure work is carried out by two persons.
1. Disconnect mixer from the mains.
2. Disconnect and wind up the connection cable.
3. Enter the operating space. DANGER! If the operating space cannot be cleaned
and disinfected, wear protective equipment according to work regulations!
4. Uninstall mixer from the basin wall or the basin floor.
5. Set the mixer down on a pallet, secure it against slipping and lift it out of the oper-
ating space.
▶ Removal is complete. Clean and disinfect the mixer thoroughly.
Mixer decommissioned.
Protective equipment put on according to work regulations.
1. Disconnect mixer from the mains.
2. Disconnect and wind up the connection cable.
3. Insert lifting equipment in hoisting gear.
4. Slowly lift mixer and remove it from the basin. During the lifting procedure, detach
the connection cable from the lifting equipment and wind it up.
DANGER! Mixer and connection cable come directly out of the fluid. Wear pro-
tective equipment according to work regulations!
5. Swivel mixer and set it down on a firm surface.
▶ Removal is complete. Clean mixer and set-down location thoroughly, disinfect if
required and store away.