Uline OHAUS RANGER 7000 Manual Del Usuario página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Smart Sampling
When connected to reference balance or 2nd platform,
smart sampling allows user to perform sampling without
manually switching platforms.
When smart sampling is turned On – Sampling will
always be performed from the reference balance
(if reference balance is on). If reference balance is off,
sampling will be performed from the main platform.
Press the button corresponding to the
perform sampling with the weight on the reference
balance (or main platform if reference balance is off).
The counting results will be displayed on the current
platform.
When smart sampling is turned Off – Sampling will be
performed on the current platform.
Accumulation
See page 7 for details about the Accumulation feature.
Input/Output (I/O) Setup
The I/O's can be customized for various user preferences.
The I/O's are defined below (defaults in bold).
NOTE: The I/O's will only work when the I/O
Option Board has been installed.
ITEM
Discrete Input 1
Off, Zero Tare, Clear Tare, Print, Unit, Accumulate
Discrete Input 2
Off, Zero Tare, Clear Tare, Print, Unit, Accumulate
Discrete Output 1 Off, Overload, Underload
Discrete Output
Off, Overload, Underload
2
Discrete Output
Off, Overload, Underload
3
Discrete Output
Off, Overload, Underload
4
The I/O option board provides two isolated inputs and
four dry-contact normally open relay outputs which can
be used for simple process weighing.
Press the
button to enter Main Menu. (See Figure 20)
Figure 20
PAGE 10 OF 105
OPERATION CONTINUED
icon to
AVAILABLE SETTINGS
With the button corresponding to the
down the list and highlight Application Mode. Enter this
submenu by pressing the button corresponding to the
icon.
In the Application Mode menu enter the Counting
submenu. (See Figure 21)
Figure 21
The Counting submenu is now displayed. (See Figure 22)
Figure 22
Select the list item and press the button corresponding
to the
icon to change the setting as desired.
CHECK WEIGHING/COUNTING
Check weighing is used to compare the weight or
pieces of a sample against target limits.
Press the
button until Check is displayed in the
upper left portion of the home screen.
Two different modes can be selected: Weight and
Pieces.
Three different methods to enter the check limits: Over
and Under, Nominal Weight Tolerance, or Nominal
Percent Tolerance.
Setup check limits according to the Check Weighing
section on page 11. Place object on the pan to check if
the weight is within the limits.
icon, go
0721 IH-7991

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

H-7991H-7992H-7993H-7994H-7995

Tabla de contenido