Recipe Formulation
Make sure the formulation mode is set to recipe.
(See Application Setup on page 16)
The information line will now show "Please recall a
recipe" Recall a recipe from the Formulation Library by
pressing the
button. (See Figure 35)
See page 26 for instructions on how to create/recall a
Library record.
Figure 35
Press the button corresponding to the
scan a barcode to start formulation. (See Figure 36)
Figure 36
The target weight in each recipe item will be used as
preset tare. Place the required weight on the pan (add
weight until the displayed value reaches zero again).
Press the button corresponding to the
confirm the weight for the current component and to
continue adding other components or scan another
barcode of the next component. (See Figure 37)
Figure 37
PAGE 15 OF 105
OPERATION CONTINUED
When all the components of the recipe have been
added, the formulation will finish and a Formulation
Result screen is displayed.
Factor and Tolerance Setup
icon or
Press the button corresponding to the
enter the Parameter screen. (See Figure 38)
Figure 38
Select the list item and press the button corresponding
to the
using the alphanumeric keypad.
icon to
The Component Factor can be set to a value between
0.20 and 5.00 with 1.0 being the default.
The Tolerance can be set to a value between 0% and
15.0% with 5% being the default.
Press the button corresponding to the
return to the Application Home screen.
NOTE: To terminate the formulation process,
press the button corresponding to the
icon. If the added weight is over the tolerance
limit, compensation will be performed
according to the setup in the configuration
(At the end, Off, Immediately).
NOTE: When the compensation is active (At the
end or immediately), if the component added
is within tolerance the capacity bar is always
green in color.
NOTE: If one component added is outside the
tolerance, the scale will do compensation for
next items. In this case, the value displayed
is not actual weight and the capacity bar will
turn red.
icon, to change the setting as desired
NOTE: Factor and Tolerance can only be set
after the formulation has started. Tolerance is
+/–, for example: Tolerance = 5% means that
the tolerance is the range –5% ~ +5%.