9. The low level symbol will appear if the tank is empty
10. Fill the ISC tank, the full level symbol will appear as soon as the maximum level threshold is exceeded. Set the operating
time to the desired time (e.g. 20min) or select NO LIMIT (using keys + and - ) is you want to finish the cleaning when the fluid
reaches the minimum level.
11. Set the time of the treatment, press OK to move to the machine's pressure adjustment display: WARNING, set the injection
system operating pressure following the vehicle manufacturer's indications; do not exceed the fuel system pressure
indicated by the manufacturer. Press OK to start the treatment
12. Press OK when the operation is completed
13. At the end of the cleaning operations press YES if you want to empty the machine's pipes (recommended) or press NO to
end the operation.
14. Connect the universal diam.8 pipe to the PRESSURE pipe and insert it in an empty container
15. Press OK, in this way the fluid is pumped at 0.5 bar for 1 minute, ignoring the level sensor so as to completely empty the
tank and pipes.
16. Connect the universal diam.8 pipe to the RETURN pipe and insert it in an empty container. In this case the fluid will empty out
through gravity without having to activate the pump.