5
Description of connections
To access the control connection terminal board, remove the motor cover as shown in
Figure 2-3-4-5 shows connection diagrams for connecting mains voltage to the motor control unit
5.1
Typical installation
2
7
1
8
It is the installer's responsibility to verify the adequacy of the cables in relation to the
devices used in the installation and their technical characteristics.
1
Power supply
2
Photocell - Receiver F4ES/F4S
3
Photocell - Transmitter F4ES/F4S
LED Flashing light R92/LED24 - FIFTHY/24
4
Power supply 24Vdc
5
Antenna
Key selector R85/60
Key pad H85/TTD - H85/TDS (connecting to H85/DEC - H85/
DEC2)
6
H85/DEC - H85/DEC2 (connecting to control unit)
Gate open indicator
7
Power supply 24V DC 3W max
Courtesy light (Potential free contact)
8
Power supply 230 Vac (100 W max)
SUGGESTIONS:
that the cables themselves are in good condition.
5
4
3
Recommended cable
H07RN-F 3x1,5 mm
Cable 5x0,5 mm
Cable 3x0,5 mm
Cable 2x1 mm
Cable 50 Ohm RG58 (max 10 m)
Cable 3x0,5 mm
Cable 2x0,5 mm
Cable 3x0,5 mm
The number of conductors increases when using more
than one output contact on H85/DEC - H85/DEC2
Cable 2x0,5 mm
Cable 2x1 mm
.
6
2
3
double insulated cable
2
2
(max 20 m)
(max 20 m)
2
2
(max 10 m)
2
(max 20 m)
(max 30 m)
2
(max 20 m)
2
(max 20 m)
2
(max 20 m)
2
55