15
Alarms and faults
PROBLEM
LED POWER off
LED POWER off
The gate does not
open or close.
Example
(EnE5)
76
ALARM
POSSIBLE CAUSE
No power.
Fuses blown.
Input mains power voltage fault.
Control initialisation failed.
Fuse F1 blown or damaged.
This message is not visible if
controller is in battery power
mode.
Overcurrent detected in inverter. Press the TEST button twice or perform 3 com-
Incorrect connection to transfor-
mer SEC1-SEC2.
Travel data acquisition error.
Calibration procedure failed.
Automation system position
with parameter
Encoder not connected.
Severe encoder malfunction.
Encoder malfunction.
Replace fuses. Always disconnect from mains
power before removing fuses.
Disconnect from mains power, wait 10 seconds
then reconnect to the mains and switch on. If the
problem persists, contact your local authorized
Pressing the TEST button it is possible to hide the
alarm temporarily and consult the control unit's
parameters.
Replace fuse.
Always disconnect from mains power before re-
mand requests in succession.
Swap connections between SEC1 and SEC2.
in alarm state.
Repeat acquisition procedure.
Allow the indicated calibration times to elapse
during self-acquisition.
Repeat acquisition procedure.
.
right hand opening gates
motor relative to passage seen from interior side).
If the position is changed and message
• Disconnect from mains power or remove the
main fuse and wait 5 seconds.
• Press and hold PROG until
and
Repeat acquisition procedure.
Replacing the encoder is recommended if the pro-
blem persists.
Press TEST button. If the error code is displayed
again, switch off the controller unit, wait 5 secon-
ds and switch on again. Replace the encoder if
the problem persists.
Press TEST button. Replace the encoder if the
problem persists.
If the unit contains dirt, moisture, insects or other
foreign matter, disconnect from mains power and
clean the board and the encoder. Replace the en-
coder if the problem persists.
ACTION
gates (position of
disappears
appears on the display.
is