Tolerance on the closing stop.
02= minimum tolerance (engine revs) ... 10= maximum tolerance (engine revs)
Advance on stop in full opening.
02= minimum advance (engine revs) ... 15= maximum advance (engine revs)
Advance on stop in full closing.
02= minimum advance (engine revs) ... 15= maximum advance (engine revs)
Setting reverse time after activation of sensing edge or obstacle detection
(crush prevention).
This sets the reverse manoeuvre time after activation of the sensing edge or the obstacle detection system. The
gate comes to a stop after reversal dues to activation of the sensing edge or obstacle detection system at the end
of manoeuvre deceleration speed. As a result, the effective reversal manoeuvre time is slightly longer than the set
time.
From 0 to 60 s.
Setting motor torque
Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a result, adjusts
obstacle detection sensitivity.
Use values below
(strong winds or very cold temperatures).
01= -35%; 02= -25%; 03= -16%; 04= -8% (reduced motor torque = increased sensitivity).
05= default motor torque setting.
06= +8%; 07= +16%; 08= +25%; 09= +35% (increased motor torque = reduced sensitivity).
Setting obstacle impact force sensitivity
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact force
exerted on obstacles is too high, reduce the value of parameter
01 = minimum obstacle impact force ... 10 = maximum obstacle impact force
N.B.
11 = minimum obstacle impact force ... 16 = maximum obstacle impact force.
70% of maximum motor torque, 1 s of reaction time. Sensing edge is compulsory.
80% of maximum motor torque, 2 s of reaction time. Sensing edge is compulsory.
Setting start acceleration during opening and closing
See chapter 13
01= the gate accelerates rapidly at start of manoeuvre ... 05= the gate accelerates slowly and progressively at start
of manoeuvre.
Enabling maximum torque boost at start of manoeuvre
If this parameter is enabled, each time the motor starts a manoeuvre, maximum torque is produced for a maximum
of 5 seconds, or for the time necessary for the gate to open by approximately 65 cm.
N.B: a motor boost mode is implemented for 2 seconds after each gate start, regardless of the setting of parameter
.
Disabled.
Enabled at start of opening manoeuvre only (including position recovery). The motor starting current function
completely closed position.
Enabled for all starts (including position recovery).
Setting motor torque during position recovery
Adjust motor torque with parameter
If position recovery is not completed, normal gate operation will not be resumed.
The response of the obstacle detection system depends solely on the values set for parameters
The response of the obstacle detection system depends on the values set for parameters
maximum current value stored during travel acquisition.
68
ONLY for particularly lightweight installations not exposed to severe weather conditions
Recommended setting for adjusting force settings correctly.
, 3 s of reaction time. Sensing edge is compulsory.
, 5 s of reaction time. Sensing edge is compulsory.
if, during position recovery, the values set with parameters
.
and
and
are
and
.
and on the