CONTACT
24(ORO)
23(COM)
25(AP)
23(COM)
26(CH)
23(COM)
27(PP)
23(COM)
28(PED)
23(COM)
29(+24V)
30(COM)
31(LAM)
30(COM)
ENC
SB
RECEIVER CARD
BATTERY CHARGER
B71/BCHP
BATTERY KIT
2x12 Vdc 4,5 Ah
Only AGM type
58
DESCRIPTION
The function of this command is determined by parameter
Open control signal input (N.O.).
IMPORTANT
automatic reclosure time count is resumed when the opening command is released.
Close command input (N.O.).
Step by step mode command input (N.O.).
The function of the control is determined by parameter
Partial open control signal input (N.O.).
Set by default to 50% of completely open position.
Power feed for external devices. See technical characteristics.
Connecting B72/BRAKE/2 power unit for BG30 High Speed versions.
(24 Vdc - duty cycle 50%).
Connector for connecting to encoder installed on motor.
WARNING! Always disconnect from electrical power before disconnecting or connecting the
encoder cable. N.B.
Connector (N.C.) for connecting release contact. If the motor release handle is opened, the
gate stops and no command signals are accepted.
is in an intermediate position, the control unit initiates the position recovery procedure (see
chapter 18).
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector for plug-in radio receiver board.
The programming buttons PR1 and PR2
10).
Connector for slot-in battery charger board.
In the event of a mains power loss, the controller unit is powered by the batteries. When battery
power is used, the message
at intervals until mains power is restored or until the battery voltage drops below the minimum
permissible limit. In this case,
unit accepts no commands.
If mains power is lost while the gate is moving, the gate stops and then automatically resumes
the interrupted manoeuvre after 2 seconds.
To reduce battery consumption, the positive power feed wire of the photocell transmitters may
be connected to terminal SC
controller unit disconnects power from the accessory devices when the gate is completely
open or completely closed.
WARNING! the batteries must always be connected to the electronic controller unit in order to
For more information, refer to the installation manual for the B71/BCHP battery charger.
.
.
.