5.2
Electrical connections
A switch or an omnipolar cut-off switch with a contact opening of at least 3 mm must be
installed on the mains power line; put the cut-off switch in OFF position and disconnect any
buffer batteries before performing any cleaning or maintenance operations.
suitable overcurrent cut-out are installed upstream the electrical installation in accordance
with best practices and in compliance with applicable legislation.
For power supply, use a H07RN-F 3G1.5 type electric cable and connect it to the terminals L
(brown), N (blue),
Strip the insulation from the ends of the power cable wires which will be connected to the
TRANSFORMER
220÷230
A
V
N
L
V
A
+
-COM
conductors in the external section to the electrical panel must be on an independent
path and separate from the connections to the command and safety devices (SELV =
Safety Extra Low Voltage).
The cables must be double insulated, strip them near the relevant connection terminals and
DESCRIPTION
Fuse 5x20 T2A.
N
L
Secondary transformer input for 26 V AC motor power (SEC1) and for 19 V power to
logical control and peripheral devices (SEC2).
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
SEC2
SEC1
Connection to ROGER brushless motor.
X-Y-Z
Connecting B72/BRAKE/2
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Y
M
X
Z
Warning! If the motor wires become disconnected from the terminal board, after recon-
necting correctly, the travel must be acquired again as described in chapter 10.
Connection to B71/BCHP
BATTERY
-
+
56
(yellow/green), located inside the control panel box.
See instructions for B71/BCHP for further information.