If the gate is stopped in an intermediate position, the lamp extinguishes twice every 15 seconds.
Set
if the output SC
Set to
if the output SC
When the gate is completely open or closed, the controller unit deactivates any accessories connected to terminal
SC to reduce battery consumption.
Set to
if the output SC
Setting deceleration during opening and closing
See chapter 13
01= the gate decelerates near the mechanical stops ... 05= the gate decelerates long before the mechanical
stops.
Setting gate opening stop constant speed approach distance
N.B.: the manoeuvre speed is set with parameter
up to the proximity of the opening stop (selected by parameter
Setting gate closing stop constant speed approach distance
N.B.: the manoeuvre speed is set with parameter
up to the proximity of the closing stop (selected by parameter
01= last 3 cm; 02= last 6 cm; ... 40= last 120 cm.
Partial opening adjustment (%)
N.B.
From 10% to 99% of total gate travel.
COR output operating mode
STANDARD operation managed by parameter
Contact closed if the motor is powered by the mains or charged battery.
(the control unit no longer accept commands).
Closed contact if none of the fault related situations 1 and 2 occurs.
Open contact if at least one of the fault related situations 1 and 2 occurs
Closed contact if the gate is not completely open.
Open contact if the gate is completely open.
Closed contact if the gate is not completely closed.
Open contact if the gate is completely closed.
Setting automatic closing time
The timer starts from the gate open state and continues for the set time. Once the set time is reached, the gate
closes automatically. The timer count restarts if a photocell is triggered.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
Enabling of management for opening with automatic re-closure exclusion.
If enabled, the exclusion of automatic re-closure only applies for the command selected via the parameter. For
, automatic re-closure is excluded following an AP command, but it is activated following
a PP or PED command.
NOTE
Disabled.
An AP (open) command activates the opening manoeuvre. With the gate fully open, automatic reclosing is exclu-
ded. Another AP (open) command activates the closure manoeuvre.
A PP (step mode) command activates the opening manoeuvre. With the gate fully open, automatic reclosing is
excluded. Another PP (step mode) command activates the closure manoeuvre.
A PED (partial opening) command activates the partial opening manoeuvre. Automatic re-closure is excluded.
Another PED (partial opening) command activates the closure manoeuvre.
Tolerance on the opening stop.
02= minimum tolerance (engine revs) ... 10= maximum tolerance (engine revs)
. After decelerating, the gate proceeds at a constant speed
)
. After decelerating, the gate proceeds at a constant speed
)
.
) or with error alert
67